Installation of Indoor, Outdoor Unit
Installation of Indoor, Outdoor Unit
Selection of the best location
1. Indoor unit
• There should not be any heat source or
steam near the unit.
• There should not be any obstacles to
prevent the air circulation.
• A place where air circulation in the room
will be good.
• A place where drainage can be easily
obtained.
• A place where noise prevention is taken
into consideration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows
from the wall, ceiling, or other obstacles.
• The indoor unit must keep the
maintenance space.
2. Outdoor unit
• If an awning is built over the unit to prevent
direct sunlight or rain exposure, be careful
that heat radiation from the condenser is
not restricted.
• There should not be any animals or plants
which could be affected by hot air
discharged.
• Ensure the spaces indicated by arrows
from the wall, ceiling, fence or other
obstacles.
6 Cassette type Air Conditioner
All manuals and user guides at all-guides.com
Ceiling
Ceiling Board
50 or
more
Floor
More than
30cm
F e
n c
o b
e o
s t a
r
c l e
s
More than
50cm
F e
n c
o b
e o
s t a
r
c l e
s
Ceiling Board
50 or
more
Unit:cm
More than
More than
30cm
30cm
More than 50cm
More than 70cm
More than
More than
50cm
30cm
More than 50cm
More than 100cm