Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

4) Form the pipings

1. Wrap the connecting portion of indoor
unit with the Insulation material and
secure it with two Plastic Bands. (for the
right pipings)
• If you want to connect an additional drain
hose, the end of the drain-outlet should
keep distance from the ground. (Do not
dip it into water, and fix it on the wall to
avoid swinging in the wind.)
In case of the Outdoor unit being installed
below position of the Indoor unit.
2. Tape the Pipings, drain hose and
Connecting Cable from bottom to top.
3. Form the pipings gathered by taping
along the exterior wall and fix it onto the
wall by saddle or equivalent.
In case of the Outdoor Unit being installed
above position of the Indoor Unit.
2. Tape the Pipings and Connecting cable
from bottom to top.
3. Form the pipings gathered by taping
along the exterior wall, and make the
trap prevent water from entering into the
room.
4. Fix the pipings onto the wall by saddle
or equivalent.
Seal a small opening
around the pipings
with gum type sealer.
Trap is required to prevent water from entering
into electrical parts.
17
Drain hose
Taping
Pipings
Connecting
cable
Power supply
cord
Seal a small opening
around the pipings
with gum type sealer.
Trap
Tabla de contenido
loading

Este manual también es adecuado para:

24k btu36k btu60k btu

Tabla de contenido