Limit switch / Encoder input
The CITY1-ECD controller allows you to connect four mechanical limit
switches (normally closed contacts) or two encoders.
The limit switches are activated by the gate panel motion and inform
the controller that each gate has reached the totally open or closed
position.
The encoders inform the controller of the exact position of each gate.
no
Inputs disabled (the controller ignores them).
It is not necessary to jumper with neutral.
EnCo
Inputs enabled as encoders
FC
Inputs enabled as limit switches.
Enabling the ADI device
This menu makes it possible to enable operation of the device
connected to the ADI connector.
no
interface disabled, any signals will be ignored
Si
interface enabled
*
PLEASE NOTE: selecting Si and pressing MENU accesses the
configuration menu for the device connected to the ADI connector.
This menu is managed by the device itself and is different for each
device. Please refer to the manual for the device.
If the Si option is selected, but no device is connected, the display will
show a series of dotted lines.
Exiting the ADI device configuration menu returns to the i.ADi option
Motor Release on Mechanical Stop
When the gate halts against the mechanical stop, the motor is
controlled for a fraction of a second in the opposite direction,
decreasing the motor gear tension.
Si
Function enabled
no
Function disabled