Different closing pre-flashing time
If this parameter has a value assigned to it, the control unit will activate
pre-flashing prior to closure for the length of time set in this menu
(while keeping the time set in the t.PrE menu for opening).
If no is selected, the pre-flashing time set in the t.PrE menu is used
during opening and closing.
If it is only desired to set pre-flashing for closure, simply set a value for
t.P.C.h. and select no for the t.PrE menu
NOTE: it is not possible to set pre-flashing for opening only.
Motor 1 power
This menu allows adjusting the motor 1 power.
The displayed value is the percentage of max. motor power.
WARNING: In case an hydraulic motor is used, set value 100.
Motor 2 power
This menu allows adjusting the motor 2 power.
The displayed value is the percentage of max. motor power.
WARNING: In case an hydraulic motor is used, set value 100.
Start off
When the gate is standstill and it begins moving, the initial inertia must
be faced, therefore, if your gate is quite heavy, its doors could not
move.
In case the SPUn (pickup) function is activated, for the first 2 seconds of
motion of each door, the control unit will ignore both Pot1 and Pot2
values and it will give motors the maximum power command in order to
overcome the gate inertia.
Soft start (slowed down)
In case this function is enabled, during the first seconds of motion of
each door, the control unit will give motors a reduced power
command, for a softer start.
PLEASE NOTE (USE OF HYDRAULIC MOTORS):
This function might NOT work correctly if hydraulic motors are
used. In this case, the functions should be disabled in the menu.
38