Kit Due Fili
A
B
C
D
CAMERA TEChNICAL FEATURES (Art. 68TC).
-
CCD 1/4" color sensor
-
3,7mm F4.5 auto-iris lens with non-adjustable focus
-
Standard video signal PAL type G, 625 lines, 50 images
-
Manual traversing on the vertical and horizontal axis
-
Horizontal resolution: 350 TV lines or Greater
-
Effective picture: 500(H)x582(V) PAL
-
Electronic iris (shutter)
-
Video output voltage 1Vpp on 75 Ohms
-
Operating temperature -5° +45°C
-
Minimum lighting level 4 lux
-
Subject lighting by means of white light LEDs
- Name-tag lighting through LEDs
-
Built-in speech unit
-
Removable terminal block
-
Monitor call push-button.
-
Output for control of lighting floodlight by relay type 0170/101
- Lock release control with same timing as command from the monitor (1
second, not adjustable).
-
Supply voltage from the bus.
-
External dimensions: 80x120x25 mm.
CAMERA TEChNICAL FEATURES (Art. 68TU).
- ¼'' CCD B/W sensor
- 3,7 mm lens with F4,5 fixed focus
- Automatic brightness control
- Manual traversing on the vertical and horizontal axis
- Standard video signal CCIR 625 lines, 50 images (EIA on request)
- Operating temperature from - 5° to + 45° C.
- Subject lighting by means of infrared LEDs
- Name-tag lighting through LEDs
- Built-in speech unit
- Removable terminal block
- Monitor call push-button.
- Output for control of lighting floodlight by relay type 0170/101
- Lock release control with same timing as command from the monitor (1
second, not adjustable).
- Supply voltage from the bus.
- External dimensions: 80x120x25 mm.
CAMERA ADJUSTMENTS (ART. 68TC, 68TU)
On the camera rear side find the following adjustments:
External
Internal
volume
volume
EN
Fig. 3
Camera activation
time
CAMERA TERMINALS (TYPE 68TU, 68TC)
CL, M)
Connection for relay type 0170/101 for additional floodlight.
It is activated for the time the camera is on.
CA, M)
Connection for additional lock push-button.
PA, M)
Connection for "open door" sensor. The sensor must be a nor-
mally open contact which closes when the door is open.
B1, B2)
BUS line
S-, S+)
Output for electric lock supply voltage (12V
*
The panel supplies a current peak IT> 1A for 10 mS, followed by a hold
current I
= 200mA for the entire duration of the lock control.
M
ENTRANCE PANEL/CAMERA
IDENTIDFICATION CODE.
If more cameras/entrance panels are installed on the building it is neces-
sary to identify the cameras with a different code. The identification code is
assigned by inserting the jumpers in the contacts as shown on the figure.
1st camera IT=0
ENTRANCE PANEL FOR VIDEO DOOR ENTRY SYSTEMS
Before installing equipment, choose location for camera entrance panel:
the camera shouid be protected from direct light (sun, car headlights, etc.)
as this may affect the quality of the picture, and may damage the camera.
This camera is equipped with infrared Leds allowing perfect picture at one
metre distance. It is advisable to protect panel with some form of weath-
erproof shelter.
ENTRANCE PANEL FOR VIDEO DOOR ENTRY SYSTEMS INSTALLA-
TION (see page 26-36)
POwER SUPPLY UNIT (TYPE 6922.1)
Technical specifications
- Supply voltage: 110 - 240 Vac
- Maximum current draw at 110 V 1 A
- Maximum current draw at 240 V 0.6 A
- Power dissipation 15 W
- BUS output voltage (1/2, B1/B2) 28 Vdc nominal (SELV - EN60950-1).
- Maximum current output: 1.6 A (1A continuous + 0,6A INT. with cycle 30s
ON - 180s OFF).
- Operating temperature -5 °C +35 °C (indoor)
- 8 x 17.5 mm module, dimensions 140 x 115 x 65mm
- for installation in consumer units with DIN rail (60715 TH35), or
wall-mounting with masonry plugs and screws provided.
Installation rules
Installation must be carried out in accordance with current regulations
governing the installation of electrical equipment in the country where the
products are located. Ensure minimum clearance distances all round the
device in order to provide sufficient ventilation. When mounted internally
of an enclosed switchboard, use a 12 x 17.5 mm module switchboard. The
device must not be exposed to water drip, splash or spray.
Caution: To avoid injury, the device must be secured to the wall following
the directions given in this document. The power supply must be connected
to the a.c. mains by way of an easily accessible double pole switch having
a gap of at least 3 mm between contacts.
Regulatory compliance
LV Directive
EMC Directive
Standards EN60065, EN61000-6-1, EN61000-6-3
*
).
2nd camera IT=1