Troubleshooting Tips - Hitachi UU610cz Manual De Instrucciones

Ocultar thumbs Ver también para UU610cz:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29
GB
TROUBLE-SHOOTING TIPS
Issue: Support Arm Assembly has problems sliding,
or handle is too "loose" or too "tight".
Solution: Remove any debris from beam slots. Re-
Adjust handle bolt tightness (see below).
To adjust the tension of the bolt, keep handle
in the down position, back nut off, adjust bolt
tension and re-tighten nut.
IMPORTANT SAFETY INSTRUCTIONS FOR USING THIS UNIVERSAL WORKSTATION
1. Read the Universal Workstation instruction
manual care-fully before assembling the
workstation and mounting the miter saw.
2. This Universal Workstation is designed to be
used with Hitachi (C8FB2, C10FCB, C10FS,
C10FSB, C10FCE, C10FCH, C10FSH, C12LCH,
C12FCH, C12LC, C12LDH, C12FDH), Bosch (3915,
3912, 4412), Delta (MS150, 36.075, 36.225,
36-085, 36-225, 36-585, M275, MS250, MS350,
36-255, 36-255L, MS450), DeWalt (DW703, DW
708, DW705, DW706, DW706, DW709), Makita
(LS1011N, LS1013, LS1212, LS1220, L51221),
Milwaukee (6490), Porter-Cable (3807, 3802),
Rigid (MS1065LZ, MS1250LZ, MS1290LZ),
Ryobi (TS1301, TS1340, TS1350DX, TS1352DXL,
MS1250LS, S1551DXL), Sears Craftsman
(137.212000, 72.24360, 315.21213, 315.212400,
315.212500, 137.212924, 315.212240,
009.23240, 009.29723), Miter Saws. Use with
additional Miter Saw models has not yet been
verified.
3. The Miter Saw should be firmly mounted to
the Universal Workstation per the instruction
manual.
4. After mounting the Miter Saw to the Universal
Workstation, align, position and balance the
Miter Saw.
5. Before use, verify that all Universal Workstation
parts are free from damage and/or deformity.
 INSTRUCTION MANUAL
Issue: "T" Track or "T" slot on Baserail is damaged.
Solution: File track or slot with flat file to remove
burr/bump.
Issue: Saw is unstable when the "Toolmount
Handles" are put in the unlock position to remove
saw.
Solution: Loosen the Toolmount Beam fasteners
(to the saw or Toolmount) and re-position the saw,
forward or back, on the Toolmount Bases.
• Re-positioning the saw will balance it, for ease of
removal and installation to the baserail, when the
handles are in the unlock position.
• For sliding miter saws, sliding and locking the
saw motor & blade to an alternate position
during removal and installation should sufficiently
stabilize the saw/toolmount unit.
6. Before use, verify that all parts or components of
the Universal Workstation are properly installed.
7. Before use, swing open each of the legs until the
brass pin clicks, locking the legs in position.
8. When mounting the Miter Saw to the Universal
Workstation, make sure that the tool mount
handles are in the "UNLOCK" position, so the
tool mount will engage with the main beam. Be
sure to hold the saw until it is secured to prevent
it from falling off the main beam. Handles should
then be tightened.
9. Before operating the Miter Saw, confirm that
the tool mount handles on both sides of this
Universal Workstation are firmly tightened
ensuring that the Miter Saw is securely mounted
to the Workstation.
10. When removing the Miter Saw from the Universal
Workstation, loosen the tool mount handles until
they rotate to the "UNLOCK" position. Hold the
Miter Saw firmly to prevent the saw from falling
off the main beam. Carefully remove the Miter
Saw.
11. Disconnect the power plug from the power outlet
when mounting or dismounting the Miter Saw to
the Universal Workstation.
Issue: Saw has rubber foot pads on the saw base
that make tool mount installation difficult.
Solution: Remove rubber foot pads.
If necessary on some saws.
Toolmount handle can be
positioned under this cavity.
Saw Base. (Side view)
Foot pads
Issue: Work support is not horizontal or parallel
with the saw table or other support.
Solution: Change angle by placing 5/16'' washer
between the support beam and "T". Re-tighten
nuts.
Support Beam
"T"
12. Do not modify the Universal Workstation in any
manner or use the Universal Workstation for any
purpose other than is stated in these instructions.
13. Do not sit or stand on the Universal Workstation.
Do not place, hang, or install anything on the
Universal Workstation other than a Miter Saw.
14. Always use this universal workstation on a level
surface. Do not use it on uneven or unstable
surfaces.
15.Before operating the mounted Miter Saw, read
the Miter Saw instruction manual carefully.
16. Because cut material may cause the workstation
to become unbalanced, always be sure the
material is supported properly. Also, if the piece
being cut is placed far beyond the work support,
workstation legs on the opposite side may
suddenly be lifted up due to weight imbalance.
To prevent this from occurring, hold the opposite
side firmly before cutting.