Should your Biotherm pro not function correctly, please perform a reset:
1. Unplug from mains
2. Plug the mains plug back in while keeping the
3. Release the
button
Attention: All programmed settings, except those for the clock, are lost. The Biotherm pro will regulate temperature
with factory's presettings (temperature 1: 25° C / temperature 2: Heating mode 25° C).
7. Causes of error
In the event of a claims issue, please perform a reset to factory settings in the first instance. If this does not eliminate
the fault or error, please identify the fault using the table below:
Error
Display indication E1
Display indication E2
Display indication E3
Display indication E5
In the event of a warranty or repair issue, please contact:
Dohse Aquaristik KG
Service department
Reiner Borghold
Industriestrasse 6
33758 Schloß Holte – Stukenbrock
Tel: +49 (0) 52 07 - 92 999 10
8. Technical data
Operating voltage:
Connected load for each slot:
Total connected load of the connection strip: Max. 3,000 W (ohmic load)
Temperature display range:
Temperature control range:
Temperature alarm range:
Temperature display accuracy:
Temperature control accuracy:
Connecting cable length:
Sensor cable length:
Cable control unit - control strip length:
Possible cause
Cable break temperature sensor 1
Cable break temperature sensor 2
Error in time settings for temperature control
on slot 1
Error in time settings for temperature control
or timer control on slot 2
230 V 50 Hz
Max. 2,000 W (ohmic load)
-9.9- 99.9° C
0.0- 60.0° C
1-10° C (00 means 'no alarm')
0.1° C
0.2° C
1.5 m
3 m
2 m
button pressed
Lösung
Send device in for repair
Send device in for repair
Ensure that the programmed times do
not overlap
Ensure that the programmed times do
not overlap