3. Programmable functions

In program mode, the functions can be configured in the following sequence.

3.1 Setting the current time

The factory presets the time at 12:00:00. The time setting is not cleared during a reset however.

3.2 Control of temperature

The temperature is regulated with a precision of 0.2° C. The temperature can be set within the range 0-60° C. The
factory presets the relative humidity to 25° C. It is possible to program up to 8 turn-on/turn-off times. The Biotherm
pro system has an automatic sorting function which will re-arrange the time periods into the correct sequential order
when exiting program mode.

3.3 Alarm setting temperature

An audible and visual alarm is triggered when the temperature exceeds or drops below the programmed desired
value. An alarm window between +/- 1° and 10° C can be set. The factory setting is the value 00 (no alarm).
Example: Temperature 25° C, alarm window +/- 3° C means that an alarm is triggered below 22° C and above 28° C.

3.4 Deactivation/Activation of audible temperature alarm

The audible alarm can be switched "ON" or "OFF". The factory setting is „OFF", as otherwise an alarm could be
triggered immediately when the system is first put into service whilst the sensor is located outside the terrarium,
where the temperature may be either too high or too low.

3.5 Choice of HEAT /COOL mode

A convenient inversion function makes it possible to switch from HEAT
an external Cooling device instead of a Heater to counteract an increase in temperature.

3.6 Timer control

As an alternative to temperature regulation, the second slot (
switch with a one-second control interval. It can be selected between ON, Aut, and Int. If ON Mode is selected the
external device at slot 2 is permanent activated. If Automatic Mode is selected up to 8 turn-on/turn-off times can be
programmed. The Biotherm pro system has an automatic sorting function which will re-arrange the time periods into
the correct sequential order when exiting program mode. If Interval mode is selected external devices are switched on
for at least 1 second and switched of for at least 30 minutes.
Attention: The Biotherm pro system can be optionally operated in the temperature 1 control (slot 1) + temperature 2
(slot 2) combination, or the temperature (slot 1) + timer switch (slot 2) combination. Programming a temperature for
slot 2 (
) will delete the programmed settings for a timer switch on slot 2 (
6
to COOL
) can be used to control external devices via a timer
) and vice versa.
. This permits connection to