Program Interval Control - Hobby Biothermpro Instrucciones De Uso

Ocultar thumbs Ver también para Biothermpro:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 82

5.4.3 Program interval control

Indicator "00:" is flashing.
To adjust interval ON Time,
use the ▲ and ▼ buttons to set the hours between 0 and 23.
button, the minutes digits "00" will flash.
Press the
Use the ▲ and ▼ buttons to set the minutes between 0 and 59.
button, the seconds will flash - "00".
Press the
Use the ▲ and ▼ buttons to set the seconds between 0 and 59.
Press
.
Indicator "00:" is flashing.
To adjust interval OFF Time,
use the ▲ and ▼ buttons to set the hours between 0 and 23.
Press the
button, the minutes will flash - "30".
Use the ▲ and ▼ buttons to set the minutes between 30 and 59*.
Press
.
If you want to finish programming, press and hold
* Settings between 0 and 59 are only possible with intervals of 1 hour or longer. For shorter intervals, a minimum of
30 minutes is preset by the manufacturer to protect electronic components.
Note: The first interval control is triggered immediately after the system returns to operating mode.
6. Werksvoreinstellung / Reset
Clock setting:
Temperature 1:
Temperature 2:
Audible temperature 1 alarm:
Visual temperature 1 alarm:
Audible temperature 2 alarm:
Visual temperature 2 alarm:
Temperature mode:
Timer mode:
14
for 3 seconds until the display returns to operating mode.
12:00:00
25° C
25° C
deactivated (Beep off)
deactivated (00 means no alarm)
deactivated (Beep off)
deactivated (00 means no alarm)
Heating
Aut (means 'automatic')
Tabla de contenido
loading

Productos relacionados para Hobby Biothermpro

Tabla de contenido