SWITCHING ON
Open the gas cock and turn the selector switch to the desired position; the burner will ignite automatically.
Should the burner fail to ignite check the lock-out push-button to see whether it is on, and if so press it so that
the boiler repeats the ignition sequence.
Following ignition, adjust both heating and hot water temperature to the desired levels by acting on the
appropriate controls.

FLUE EXHAUST CONNECTION

CONNECTION TO THE CHIMNEY - VERSION XILO 20 MC W TOP
The boiler is envisaged being connected to a chimney and/or a flue pipe; the combustion fumes can also be
discharged directly outside. If you connect up to a vertical flue, a cover must be fitted.
The joining to the chimney or flue pipe must be made with a smoke conduit having the following features:
G of being sealed airtight, as with the connection to the chimney itself;
G of being of suitable material;
G of being connected within sight;
G of having changes in direction, not more than 3 no., which must be carried out with internal angles greater
than 90° and with the use of curved elements;
G of not having any intercepting devices;
G of having the axis at the entrance of the terminal section perpendicular to the opposite internal wall of the
chimney;
G of being firmly fixed and sealed at the entrance, without protruding beyond the inner walls of the chimney;
G of receiving preferably one boiler only;
G of observing the local regulations in force.
WARNING:
The unit is fitted with FLUE CONTROL to monitor flue draught. This safety device shuts down the boiler if there
is a risk of combustion fume backflow into the room by cutting off the gas supply at the infeed point. This device
must never be deactivated. If combustion fumes re-enter the room they may cause chronic or acute intoxication
and can be fatal. If the Flue Control device is changed use only original spare parts. If the device trips
repeatedly check for proper fume outflow via the chimney flue and contact a Lamborghini Service Centre.
NO
Flue pipe or
chimney
YES
Ø 132,5 mm
H max. 2500 mm
4
39
3%