MULFUNCTIONS AND ADJUSTMENTS
Should the boiler shut down it must be reset by rotating functions selector switch to position A.
Legend:
On
Off
JP1
On LPG - Off Methane
On
JP2
Max. hot water adjustment 60°C
On
JP3
(post-circ. off)
heating
On
JP4
Heating timer off
Resistor jumper cut, floor heating temp. set to 30/40°C.
JP5
Resistor jumper uncut, temperature 35/80°C
RLA
Slow ignition adjustment
increase
R max.
Max. heating power adjustment
increase
Should the flue control trip, re-ignition will be disabled for 20 minutes. The timing can be reset to zero by
switching the power off and then back on via the function selector.
Constant light: Ignition shutdown
Fast flashing light: TST shutdown
Off
Max. hot water adjustment 50°C
Off
post-circ.
on 2.5 minutes
Off
heating timer on 2.5 minutes
A
Constant light: No water
Fast flashing light: Sensor fault
Slowly flashing light:
Air pressure switch (MCS)
Flue Control (MC)
J P 1
R L A
35
J P 3
J P 5
J P 4
J P 2
R m a x .