Conversion to another type of gas
Check the Installation
Check operation of electric igniters. Check flame
characteristics. Flame should be blue with no yellow tip.
Yellow Flames:
Further adjustment is required.
Yellow Tips on Outer Cones:
Normal for LPG Gas.
Soft Blue Flames:
Normal for Natural Gas.
If the flame is completely or mostly yellow, verify that the
regulator is set for the correct fuel. After adjustment,
retest.
Some yellow streaking is normal during the initial start-
up. Allow unit to operate 4-5 minutes and re-evaluate
before making adjustments.
Removing the appliance
Disconnect the appliance from the power supply. Close
the gas shut-off valve. Remove the silicone joint from
appliances installed flush. Push out the appliance from
below.
NOTICE
Appliance damage! Do not lever out the appliance at the
frame from above.
14
Conversion to another type of gas
C o n v e r s i o n t o a n o t h e r t y p e o f g a s
T his gas stovetop corresponds to the categories
specified on the rating plate. By changing nozzles, it is
possible to convert the appliance to any of the gases
listed on the plate. The conversion kit can be obtained
from our customer service. With some models, the
conversion kit is included in the scope of delivery.
Only a licensed specialist is authorized to switch the
appliance to another gas type.
Before carrying out the conversion, turn off the electricity
and gas supply.
Replacing the Main Control Nozzles: Wok Burner
1.
Remove the pan supports and all burner parts.
2.
Unscrew the fastening nuts from the cooktop (3 nuts –
WAF 7), and carefully lift up the cooktop to remove it.
3.
Remove the securing clips from the burner pipes. Pull
out the burner pipes. Unscrew the screw in the air
regulating sleeve. Remove the nozzle retaining head.
4.
Pull off the nozzle and O-ring for the inner burner ring
by hand. Unscrew the nozzle for the outer burner ring
(WAF 10).