1
User
The CPX−FB33 and CPX−FB34 bus nodes for CPX terminals
are specified for use as stations on the PROFINET IO
Industrial Ethernet system exclusively.
The limits specified in the technical data must be complied
with. See the description for P.BE−CPX−PNIO−... bus nodes
and the P.BE−CPX−SYS−... CPX system description for more
detailed information.
Warning
S Switch off the power supply before assembling or
disassembling modules or plugging plug connectors
together or separating them (risk of operative mal
function or damage).
S Use only power sources which guarantee reliable
electrical isolation of the operating voltage in accord
ance with IEC/DIN EN 60204−1. Observe also the gen
eral requirements for PELV circuits in accordance with
IEC/DIN EN 60204−1.
S Connect an earth wire with sufficient cable cross sec
tion to the terminal marked with an earth symbol.
S The CPX bus nodes contain electrostatically sensitive
devices. For this reason, do not touch any compon−
ents. Observe the handling specifications for elec
trostatically sensitive devices.
Note
Only put a completely assembled and wired CPX ter
minal into commission.
Festo CPX−PNIO 0710NH English
instructionsEnglish
17