Installation Guide
Plumbing
Terminal Description
CAUTION: Low-voltage Hazard.
Can cause equipment damage.
Disconnect HVAC equipment before beginning
installation.
A four-block wiring terminal is located on the exhaust end of
TrueDRY.
*
Note: Outer screws secure block to TrueDRY DH65. Not for wiring.
DHUM:
Compressor and fan operation for dehumidification.
COM:
24V common.
FAN:
Fan activation only for ventilation.
EXT:
External accessory control (motorized damper, dehu-
midistat).
69-2089EFS—01
Connect 1/2-in. drain tube to male connection drain
outlet. Secure drain tube to connector with hose clamp.
Run drain hose continuously downhill to an approved
drain or condensate pump.
OVERFLOW
SAFETY
SWITCH