Switchboard set to EXTERNAL mode (led in key
-
Key in the required user number, (i.e. 77) on the main entrance panel keypad.
-
Confirm with button "C".
-
Terminal +L on the entrance panel activates.
-
The digital code corresponding to user number 77 is routed along line 1 to the
cable riser.
-
The digital call code for user number 77 is recognised by the switchboard and
terminal +I is momentarily activated to switch off any activated monitors.
-
The message "STOP" is displayed on the switchboard.
-
Switchboard terminal I activates to keep the switchboard monitor deactivated.
-
The call code for user number 77 is regenerated and re-routed to the monitor
cable riser.
-
The phonic circuit for monitor number 77 connects to the cable riser.
-
Switchboard terminal CH activates for the call time set for the switchboard
and routes the call signal along line 3 of the cable riser.
-
The entrance panel phonic circuit connects at the end of the call time set for
the entrance panel itself.
-
If the monitor handset is not lifted the entrance panel activates the reply time
counter.
-
If instead the monitor handset is lifted within the set reply time, the entrance
panel activates the maximum conversation time counter.
-
The two auxiliary functions and the door lock opening function can all be
activated when the handset is lifted or set down. The two auxiliary functions
may also be activated when the monitor has not been called.
-
When the door lock release button is pressed
code corresponding to the monitor user number (77) is transmitted by the
monitor to the cable riser. The entrance panel from where the call originates,
then identifies the code and activates terminal S for the set door lock activa-
tion time. Power supplier terminal S1 therefore de-energises to zero Volts for
the time terminal S is activated.
-
If the "door lock enable" parameter for the switchboard is set to 0001, the
switchboard will also activate its own terminal S when the door lock release
button is pressed
.
- When the video camera button is pressed
F2 corresponding to the monitor user number (77) is transmitted by the mon-
itor to the cable riser. The switchboard and entrance panel then identify the
code and activate their respective terminals F2 for the activation time set for
auxiliary function F2.
- When the light button is pressed
corresponding to the monitor user number (77) is transmitted by the monitor
to the cable riser. The switchboard and entrance panel then identify the code
and activate their respective terminals F1 for the activation time set for auxil-
iary function F1 (parameters -07- and -10-).
- Once the reply delay time or maximum conversation time has elapsed, the
main entrance panel connected to the monitor transmits a reset code to dis-
connect the monitor. The switchboard thus activates terminal +I to switch off
the monitor and clear the "STOP" message.
- The same sequence occurs if the monitor handset is replaced before the
maximum conversation time has elapsed. Five seconds after the handset
is replaced, the entrance panel transmits a reset code and the switchboard
activates terminal +I.
Switchboard set to INTERNAL mode (led in key
entrance panel.
- Key in the required user number, (i.e. 77) on the main entrance panel keypad.
- Confirm with button "C".
- Terminal +L on the entrance panel activates.
- The digital code corresponding to user number 77 is routed along line 1 to the
cable riser.
- User number 77 is displayed on the right hand display of the switchboard and
the acoustic call signal is activated.
- If switchboard terminal I is activated, the terminal deactivates.
- The switchboard monitor switches on and displays the image filmed at the
entrance panel.
- The switchboard phonic circuit connects to the entrance panel.
- If the switchboard handset is not lifted the entrance panel activates the reply
time counter.
- If instead the switchboard handset is lifted within the set reply time, the en-
trance panel activates the maximum conversation time counter.
- When button
is pressed, the switchboard transmits the code for auxiliary
function F2. The entrance panel then identifies the code and activates termi-
nal F2 for the activation time set for auxiliary function F2.
- Once the reply delay time or maximum conversation time has elapsed, the
main entrance panel transmits a reset code to disconnect the switchboard.
The switchboard thus activates terminal I to switch off its monitor.
- The same sequence occurs if the switchboard handset is replaced before
the maximum conversation time has elapsed. Five seconds after the handset
illuminated).
, the door lock release
, the code for auxiliary function
, the code for auxiliary function F1
switched off) for calls from
is replaced, the entrance panel transmits a reset code and the switchboard
activates terminal I.
Switchboard set to INTERNAL mode for calls from internal units (monitors or
interphones).
- When the monitor is switched off, press the door lock release button
.
- The switchboard call digital code corresponding to the monitor number (i.e.
77) is routed along line 1.
- User number 77 is displayed on the left hand display of the switchboard and
the acoustic call signal is activated.
- If the porter wishes to call the monitor which has placed the call, he must:
- Transfer user number 77 to the right hand display using button
- Press the call button
.
The following sequence then occurs:
- The digital code corresponding to user number 77 is routed along line 1 to the
cable riser.
- Switchboard terminal T activates to switch on the video camera unit.
- If switchboard terminal I is activated, the terminal deactivates.
- Terminal +I momentarily activates to switch off any activated monitors.
- The phonic circuit for monitor number 77 connects to the cable riser.
- Switchboard terminal CH activates for the set call time and routes the call
signal along line 3 of the cable riser.
- The switchboard phonic circuit is connected at the end of the call time.
- If the monitor handset is not lifted the switchboard activates the reply time
counter.
- If instead the monitor handset is lifted within the set reply time, the switch-
board activates the maximum conversation time counter.
- The two auxiliary functions can both be activated when the handset is lifted or
set down. The two auxiliary functions may also be activated when the monitor
has not been called.
- Once the reply delay time or maximum conversation time has elapsed, the
switchboard connected to the monitor transmits a reset code to disconnect
the monitor. It thus activates terminal +I to switch off the cable riser monitor
and terminal I to switch off its own monitor. It also de-activates terminal T to
switch off its video camera.
- The same sequence occurs if the monitor handset is replaced before the
maximum conversation time has elapsed. Five seconds after the handset
is replaced, the switchboard transmits a reset code and activates the corre-
sponding terminals.
N.B.: in installations fitted with a main entrance panel and switchboard, the
main entrance panel call signal activation time must be at least a second
longer than the time set for the switchboard to prevent the call signal from
returning to the main entrance panel receiver.