Optical Safety Edge Transmitter (Ose); Technical Data - SOMFY HOME MOTION ROLLIXO RTS Manual De Instalación

Ocultar thumbs Ver también para HOME MOTION ROLLIXO RTS:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Rollixo RTS

optical safety edge transmitter (osE)

Press the PROG SW4 button on the safety edge transmitter. Press it down
until the indicator light goes out (the indicator light is permanently lit while the
button is pressed).
The transmitter indicator light will illuminate:
• first green to provide information on the assembly configuration
• then red to indicate any faults.
transmitter indicator light
status
Diagnostics
1 green flash
Operation without magnet (default)
2 green flashes
Operation with lower magnet only
3 green flashes
Operation with upper magnet only
4 green flashes
Operation with upper and lower magnets
Permanently red
Faulty OSE transmitter
OSE transmitter indicator light fixed red: transmitter faulty
Actions
transmitter indicator light status
LED 1 and LED 2: flash green once then
Open the OSE
flash orange for 1 to 30 seconds, then
transmitter
flash green for 5 seconds.
housing.
LED 1 and LED 2: flash orange for 1 to
Remove and refit
2 minutes
the battery
LED 1 and LED 2 remain off
LED 1 and LED 2 remain off
Open the OSE
transmitter
housing.
Press button SW2
LED 1 and LED 2 light up red briefly
until LED 1 lights
up permanently
red.
LED 1 lights up green then LED 2 lights
up permanently green for 8 seconds.
GENERAL tEChNICAL
sPECIfICAtIoNs
Power supply
Electrical insulation
Maximum motor output
Safety fuse for motor and integrated lighting
Somfy radio frequency
Number of storable remote controls
Operating temperature
Protection rating
CoNNECtIoNs
Mains power supply cable
Integrated courtesy lighting
Safety inputs
Self-test output for safety devices
Wired control input
Orange light
Alarm siren output
oPERAtIoN
Control buttons
Automatic closing mode
Downgraded operation mode control
Maintenance assistance
Copyright © 2012 Somfy SAS. All rights reserved
Repair / Actions
Check that there are no magnets installed on the door runner.
Check for the presence of magnet(s) on the door runner.
Check that the safety edge transmitter and the magnet(s) are installed on the right-hand side
of the door.
Perform the installation with magnet procedure again.
See table below to identify the fault.
Result/troubleshooting
The battery and the transmitter are operating correctly.
If the problem persists, replace the battery (part no. 1782078).
The battery is low, replace it (part no. 1782078).
The OSE transmitter is no longer operating and must be replaced (ref. 1781245). Follow the
instructions provided with the OSE transmitter then carry out commissioning as described on
page 9.
Check that the rubber on the safety edge is not crushed and repeat the check.
Check the photoelectric sensor wiring and repeat the check.
If the problem persists, replace the optical cells by following the instructions provided with the
cells.
Photoelectric sensors:
- for a strip of 3 m max.: ref. 9016767
- for a strip of 7 m max.: ref. 9015560
The OSE transmitter and the photoelectric sensors are operating correctly.
If the problem persists, replace the battery (part no. 1782078).
3 inputs for: - Wired safety edge: optical, resistive
Up-Stop-Down buttons in the control panel
Automatically activated when lowering if a fault is detected on a safety device
Battery
196-253 V 50-60 Hz
Category 1
230 V - 1250 W
5 AT - 250 V - spare fuse supplied
433.42 MHz
32
-20°C/+60°C
IP 20
2 m - IEC sheet (phase-neutral-earth)
E14 - 25W max. - 230V
- Fall protection device
- Photoelectric cells
For cells
NO dry contact - sequential operation
24V - 4W max.
Yes
Yes
Real time status with 5 indicator lights
21

Capítulos

Tabla de contenido
loading

Tabla de contenido