Rollixo RTS
orange LED (part no. 9017842)
Dipswitch 3 receiver set to ON → 2-second warning activated
Dipswitch 3 receiver set to OFF → No warning
ge
KeySwitch
9
10
4 W max.
Alarm
It is essential to have programmed at least one remote control. The alarm can only be stopped with a memorised remote control.
• Installing and connecting the alarm
Mount the alarm to the receiver with the bolt provided.
Connect the alarm connector.
• Activating/Deactivating the alarm
Dipswitch 5 receiver set to ON → Alarm activated
Dipswitch 5 receiver set to OFF → Alarm deactivated or not connected
• Alarm operation
The alarm is triggered for 2 minutes if the door is raised manually.
No movement of the door is possible when the alarm is sounding.
When the alarm sounds, press a button on a remote control memorised in the
receiver to stop it. The alarm can only be stopped with a memorised remote
control.
• Alarm operation test
Press simultaneously on buttons
The alarm triggers briefly to indicate that it is activated.
• optional: lower magnet
A lower magnet may be installed if the alarm sounds erratically (see page 9).
Copyright © 2012 Somfy SAS. All rights reserved
24V C
Flash
24V dc
11
12
13
14
15
16
17
and
on the receiver.
STOP
key lock
Successive presses cause the motor to move (initial position: door closed) as
per the following cycle: open, stop, close, stop, open, etc.
7
1
2
3
4
STOP
Safety Edge
KeySwitch
Flash
24V
Sec
8
9
10
11
12
13
14
Prog
1
15