Rollixo RTS
ADvANCED PARAMEtER sEttING
Different operating modes
2 operating modes are available:
Sequential (default mode)
Semi-automatic
2 automatic closure options are available for the door:
Closure time delay
Cell locking
Note: by default, no automatic closure option for the door is activated.
The installation of photoelectric cells is mandatory in the event that an automatic closure option is activated.
Programming operating modes
Changing the operating mode
Briefly press the M button to switch from sequential mode to semi-automatic mode.
Indicator lights
Mode activated
M1
M2
M3
Sequential
Semi-automatic
Note: M3 indicator light, unused
Activating automatic closure
Short press on the T button to activate automatic closure.
Automatic closure option activated
Indicator light
Closure time delay
Cell locking
No option active
Modification of the automatic closure time delay
The automatic closure time delay can be adjusted from 5 seconds to
2 minutes (20 seconds by default)
To modify the automatic closure time delay, one or other of the
automatic closure options must be activated.
[1]. Run the timer by pressing and holding down the T button for 2
seconds.
Indicator light
flashes rapidly.
[2]. Stop the timer by briefly pressing the T button when the desired
time delay is obtained.
Indicator light
flashes slowly or comes on permanently.
16
Each press on the remote control causes the motor to move (initial position: door closed) as per the following cycle:
open, stop, close, stop, open, etc.
In semi-automatic mode:
- pressing a button on the remote control during opening has no effect,
- pressing a button on the remote control during closing causes it to reopen.
With automatic closure time delay:
- the door is closed automatically after the programmed time delay has elapsed (20 s, by default),
- pressing a button on the remote control interrupts the movement taking place and the closure time delay (the door
remains open).
After the door is opened, movement in front of the cells (safe closure) will close the door after a short timed delay
(fixed at 5 seconds).
If there is no movement in front of the cells, the door will close automatically after the programmed closure time delay
(20 s, by default).
If there is an obstacle in the cells' detection zone, the door will not close. It will close once the obstacle is removed.
[1]
2s
[2]