30 | WBE 4420 | Settings and Service
3.4

Factory calibration

i
We recommend carrying out the factory calibration
during software updating, replacement of the
pick-up, of the measurement unit or of the board,
following the sequence below:

1. Flange calibration

2. Calliper gauge/measurement arm calibration

3. Calibration with sample weight.

!
At the end of every calibration carry out a control
measurement.
3.4.1

Recalling of the calibration menu

1. From the "Settings and Service" menu select
Calibration and confirm by pressing <OK>.
2. Enter password: <z> <u> <v>.
"
The calibration menu is displayed.
Calibration with sample weight.
Flange calibration
Back to main page.
Calliper gauge and measurement arm calibration
3.4.2
Flange calibration
i
Follow the instructions for the standard calibration
(see chap. 5.4.2).
3.4.3
Calibration of electronic calliper gauge/
measurement arm
i
Follow the instructions for the standard calibration
(see chap. 5.4.3).
|
1 695 655 424
2010-04-30
3.4.4
Calibration with sample weight
i
Keep to the indications displayed on the monitor.
1. Select Calibration with sample weight and confirm
by pressing <OK>.
« Calibration is started.
2. Bring the calliper gauge on the flange.
3. Bring the calliper gauge back to stand-by position
4. Press <START> or close the wheel protection cap.
« Measurement is started.
5. Apply the sample weight on the internal side of the
flange.
6. Press <START> or close the wheel protection cap..
« Measurement is started.
7. Remove the sample weight from the internal side
of the flange and apply it on the external side (12
o'clock).
8. Press <START> or close the wheel protection cap.
« Measurement is started.
9. Turn the flange until the weight is in 12 o'clock
position.
10. Press <OK>.
"
Calibration is completed.
i
The performed calibration is automatically and
permanently saved.
i
After having carried out factory calibration with
sample weight, access the standard calibration menu
(see chap. 5.4.1) and perform the calibration with
wheel and sample weight (see chap. 5.4.4).