Pressure differences
The pressures of the cold and hot water connec-
tions must be balanced.
Operation
The mixer is activated by lifting the lever handle.
Temperature limitation
The temperature is limited by the safety check
to 38° C (100° F). If a higher temperature is
required, it is possible to override the safety stop
by depressing the safety button.
Adjustment (see page 10)
Correction is necessary if the temperature mea-
sured at the take off point differs from the tem-
perature set on the scale. To adjust temperature
proceed as follows:
Turn the setting knob until water at a temperature
of 38° C comes out of the outlet. Loosen screw of
setting knob. Remove setting knob and turn to the
38° C position. Attach setting knob again and
tighten the screw.
Safety Function (see page 10)
The desired maximum temperature for example
max. 42° C can be pre-set thanks to the safety
function.
Technical Data
Operating pressure:
Recommended operating pressure: 0,2 - 0,5 MPa
Test pressure:
(1 MPa = 10 bars = 147 PSI)
Hot water temperature:
Recommended hot water temp.: 65° C
Rate of flow by 0, MPa (see page 14)
Handshower (5)
Handshower + body showers (1)
Body showers, 2 jets (3)
Body showers, 4 jets (2)
Body showers, 6 jets (4)
English
max. 1 MPa
1,6 MPa
max. 80° C
16 l/min
23,0 l/min
12,6 l/min
16,8 l/min
21,6 l/min
Flow heater
Applicable for flow heaters at min. 24 kW and
0,15 MPa flow pressure before the Shower panel
and a minimum through flow of 7 l/minute. Only
one consumer possible, not two simultaneously.
Maintenance
The non return valves (22) must be checked regu-
larly according to DIN EN 1717 in accordance
with national or regional regulations (at least once
a year).
At this time, please also check the filter (14) situa-
ted on the MTC-ther-moelement (14). After assem-
bling the MTC-thermo-element, it is necessary to
check the water temperature at the take off point
as described under the headline „adjustment".
Before the adjustment, please check, if the warm
water supply is activated and the maximum tempe-
rature of the warm water is available at the take
off point.
To guarantee the smooth running of the thermostat,
it is necessary from time to time to turn the thermo-
stat from total hot to total cold.
Spare parts (see page 21)
1
handshower
2
support, assy
3
hose 1,60 m
4
upper cover
5
escutcheon
6
body shower Massage jet
7
body shower Normal spray
8
handle
9
handle for thermostat
10 flange
11 frontcover
12 sleeve
13 adapter for handle
14 thermostat cartridge
15 nut
16 cartridge on/off control
17 sealing set
18 connection hose
19 fixing set for hose connection
20 mounting set
21 hose connection angel (2)
22 non return valve
23 filter
28519000
97024000
28276000
97324000
97326000
28408000
28406000
10490000
38391000
97858000
97859000
95032000
97108000
94282000
96945000
96645000
95037000
13099000
94158000
96179000
25967000
97350000
97973000