Danger
Risk of injury! Before doing any work on the
machine:
Set the appliance switch to "0".
Pull out the mains plug.
Fault
Motor/pump do not start or
switch off automatically when the
machine is on.
Indicator lamp "Dirt water tank
full" is glowing.
Working pressure of min. 3 bar is
not building up.
Cleaned steps are too wet.
Washed steps are not clean.
Indicator lamp "Brush motor
overload" is glowing.
Troubleshooting
Lock the rear wheels.
Drain off and disose the remaining deter-
gent fluid.
Drain out the dirt water and dispose it off.
Remedy
Dirt water reservoir is full; empty it.
Press the foot pedal.
Dirt water reservoir is full; empty it.
If fresh water reservoir is empty, then fill it up (35 litres).
Check pipes to see if there are any leaks. If required, get
it sealed by customer service.
Check the nozzles.
Get customer service to clean the pump.
Check the combs for wear, replace if required.
Check the condition of the seal of the dirt water reservoir
for damages, replace if required.
Check the intake brushes for wear, replace if required.
Check suction nozzles and hose for blockages; clean if
required.
Check whether the wastewater reservoir lid is completely
closed.
Check whether the correct combs have been installed.
Check detergent nozzles to see if they are blocked; clean
or replace if required.
Check the condition of the seal of the dirt water reservoir
for damages, replace if required.
Check the brush rollers and intake brushes for wear, re-
place if required.
Check detergent. Check the concentration of the deter-
gent solution.
Check the intake brushes for wear, replace if required.
Check whether the wastewater reservoir lid is completely
closed.
Check whether the correct combs have been installed.
Set appliance switch to "0", then turn it back to the de-
sired operating position. If the fault recurs often, call cus-
tomer service.
Remove belts or cords from brushes.
15