Shutting Down - DeWalt DPE3800 Manual De Instrucciones

Ocultar thumbs Ver también para DPE3800:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Shutting Down

1. Place the engine START/RUN/OFF switch (O) to the OFF
Position.
2. Place the fuel valve lever (N) in the OFF postion.
3. If chemicals were applied, place the chemical hose into a
container of clean water and draw clean water through chemical
injection system to rinse system thoroughly.
cAutIoN: Risk of property damage Failure to do so could cause
damage to the pump.
4. Turn engine off. Refer to the engine instruction manual.
cAutIoN: Risk of property damage. NEvER turn water supply off
while pressure washer engine is running or damage to pump will
result.
5. Turn water source off.
6. Pull trigger on spray gun to relieve any water pressure in hose or
spray gun.
7. Refer to storage for proper storage procedures.
MAInTEnAncE
WARNING: Risk of burning. When performing maintenance, you
may be exposed to hot surfaces, water pressure or moving parts that
can cause serious injury or death.
WARNING: Risk of fire. always disconnect, spark plug wire, let the
engine cool and release all water pressure before performing any
maintenance or repair. The engine contains flammable fuel. Do not
smoke or work near open flames while performing maintenance.
WARNING: to reduce the risk of serious personal injury, turn
tool off and and remove battery pack before making any adjust-
ments or removing/installing attachments or accessories.
All manuals and user guides at all-guides.com
To ensure efficient operation and longer life of your pressure washer,
a routine maintenance schedule should be prepared and followed.
If the pressure washer is used in unusual conditions, such as high
temperatures or dusty conditions, more fre quent maintenance
checks will be required.
Engine
Consult the engine instruction manual for the man u fac tur er's recom-
mendations for any and all maintenance.
notE: The pressure washer frame is equipped with an oil drain
hole to help make changing the engine oil easier.
Pump
notE: The pump was filled with oil at the factory.
1. Change pump oil after the first 10 hours of operation and every
to cHEck oIL
1. The oil level should come to the
HoW to cHanGE PuMP oIL
1. Loosen pump oil plug (H).
2. Place a container under the oil
3. Remove pump oil drain plug.
4. After oil is drained, replace oil
5.
6. Replace pump dipstick/oil plug and tighten securely.
20
250 hours thereafter.
dot in the middle of the sight
glass (Z).
drain plug (AA).
drain plug. Tighten securely.
Remove pump oil plug and fill with 14 oz. (414 ml) of DP70 pump
oil. If DP70 is not available use 30W non-detergent oil.
H
Z
AA
Tabla de contenido