Operating Instructions
IN4000 Standard
Fig. 3: Test mode
on the IN4000
Standard safety
switches
Tab. 5: Electrical
input parameters
for the IN4000
Standard safety
switches
© SICK AG • Industrial Safety Systems • Germany • Subject to change without notice • 8010934/YTC9/2016-04-01
Product description
3.5
Signal behaviour
At the TE input on the safety switch there must be a test
signal that meets the following conditions (cf. Fig. 3):
PSDI input (TE)
PSDI ouput (A)
The electrical input parameters are compatible with the
output parameters in compliance with EN 61 131-2
(nominal current 0.1 A and nominal voltage 24 V):
Logical "1"
Logical "0"
Permissible test
pulse duration
If the actuating element is in the enable zone and
there is no sensor error, the test input signal is for-
warded to the output with the time delayed. The out-
put parameters are compatible with the parameters
for the input in compliance with EN 61 131-2 type 1
or 2:
≥ 11 V, < 30 V
5V
≤
1.0 ms
Chapter 3
T1 ≥ 50 ms
T2 ≥ 50 ms
T = 100...500 ms
Td = 1.0...1.5 ms
Input current 3 mA
Residual current
1 mA
69