Atlanta Attachment Company 2211MA Manual De Usuario página 24

Dobladillador semiautomático de 2 agujas
Tabla de contenido
Technical Manual & Parts Lists
PARAMETER
RANGE
Do this first
*****
290
000
0-254 st
002
0-254 st
003
0-254 st
004
0-254 st
005
0-254 st
009
0-1
013
0-1
014
0-1
023
0-1
026
100
0-254 st
110
70-390 rpm
111
200-9900 rpm
112
200-9900 rpm
113
200-9900 rpm
114
200-9900 rpm
115
70-1500 rpm
116
70-500 rpm
117
400-9900 rpm
118
400-9900 rpm
128
0-2000 ms
129
0-3
130
0-1
132
0-1
133
0-1
134
0-1
137
0-1
161
0-1
191
0-1
193
0-1
202
0-500 ms
204
1-100
207
0-55
208
0-55
232
0-1
235
0-1
240
13
241
26
254
1-100
263
264
265
0-2550 ms
270
0-5
272
020-255
281
0-2550 ms
288
0-2550 ms
436
401
Front panel LED's:
LED 1: Off; Puller in chaining speed at start of sewing.
LED 2: On; Puller in chaining speed after parameter 004.
LED 3: On; LE chain cut enabled.
LED 4: On; TE chain cut enabled.
LED 5: Off, Enabling foot lifting in middle of seam.
LED 6: On, Enabling of foot lift at end of seam.
LED 7: Off, Stop at needle down.
LED 8: On, Stop at needle up.
Stepper Speed Settings:
speed 1 (sewing): 118
speed 2 (chaining): 140
19
211M Parameter Settings - CUT LE & TE (STANDARD)
VALUE
****
7
Mode of operation. MUST SET THIS PARAMETER FIRST!
30
Puller duration in chaining speed (must be same as parameter 003)
20
LE cut delay from sew start
30
TE cut delay from start of chaining
20
Delay before puller changes to chaining speed.
1
Number of stitches for end of seam filtering.
1
Automatic cycle of machine from sew sensor.
1
Enabling of chain cutter.
0
Enabling of thread wiper.
1
Raising of presser foot at end of chain cut.
0
Treadle configuration - non-analog
0
Softstart duration of sew head.
200
Positioning speed.
5000
Maximum speed when "129" is 0, 1, or 2.
5000
Start speed until LE cut
5000
Speed setting for chaining duration.
5000
Speed setting for end of sewing delay.
70
Speed setting for softstart duration.
500
Speed at TE cut
5000
Speed setting for folder blowers.
5000
Maximum speed when "129" is 3.
30
Presser foot down delay from sew sensor covered.
Automatic start mode. 0=start & run with foot pedal only, no sensor; 1=run with pedal speed
control and sensor (end of cycle at pedal speed); 2= run with pedal speed control and sensor
2
(end of cycle at full speed); 3=fully automatic mode using sensor only (pedal is locked out). Note:
If E-Stop switch is up, unit is fully automatic with a setting of 2.
0
Enabling of end of seam filtering.
1
Automatic cycle of machine from sew sensor
1
Enabling of autotrim at end of cycle.
0
Enabling of softstart.
1
Enabling of folder blowers.
0=cw/1=ccw Motor rotation
1
End of sew after chain cut
0
Enabling of chaining speed at TE
150
Sew head on delay from presser foot down.
100
Foot lift modulation
55
Low speed braking.
55
High speed braking.
0
Chain cutter (Off=scissors, ON=double solenoid)
0
Enabling of speed reduction during TE cut.
13
Enables folder blower sensor.
26
Enables stacker sensor.
100
Default upper limit for 204, 100%
1
1
Inverts logic of folder blower output.
1
0
Inverts logic of stacker output.
40
Stacker door on duration.
2
External handwheel sensor configuration.
Drive ratio between motor pulley and handwheel pulley. If handwheel pulley is smaller than motor
pulley, increase this value to slow down sewing head until measured speed matches speed set
1000
with parameter 111. (For Yamato and Pegasus, setting should be 100; for Rimoldi, setting
should be 124)
5
Duration of chain cutter.
0
Delay before foot up at end of seam
0
Must use code "5913". This disables an input that was causing box to reset itself.
0-1
CHANGE FROM 0 TO 1 TO SAVE PARAMETERS
DESCRIPTION
Perform a master reset before programming, see below
To Perform Master Reset of Parameters:
1. Power on holding down the "P" button till "COD" is displayed.
2. Press ">>" once and enter the number "5913"
3. Press "E" twice and "093" is displayed.
4. Press "+" once, "094" is displayed.
5. Press "P" to exit programming mode with all default values.
Programming Instructions:
1. Power on holding down the "P" button till "COD" is displayed.
2. Press ">>" once and enter the number "5913"
3. Press "E" once and "2.0.0." is displayed this is a parameter
4. Proceed to the parameter to be changed and press "E".
5. The value now shows in the screen, adjust to desired value.
6. Press "E" to enter value and continue with parameter setting.
7. Repeat for other parameters, press "P" once when complete.
8. Run sewing head to save parameters before powering down
Tabla de contenido
loading