System message
Functions that are still
available
Motor blocked
None
Er44
(The control system
attempted to start up the
motor three times - 5 times
per attempt)
More than 960 cleaning
Er55
− Manual cleaning
cycles in 48 hours
− Automatic mode
− Time-dependent cleaning
Switch element for rinsing
None
Er66
pump in the control system
overheated
Permissible water level in the
− Manual cleaning
Er77
filter container is reached
− Automatic mode
− Time-dependent cleaning
Possible cause
Remedy
Filter drum rotating sluggishly or
− Clean edge of the drum/drum seal and grease edge of
jammed
− Ensure that the rollers move smoothly
− Remove larger particles (e.g. snails, stones) from the
The lips of the drum seal were
Disassemble the drum and ensure that the drum seal is
squeezed when the drum was installed.
positioned correctly during re-assembly
The drum load is distributed unevenly
Align the container horizontally
Temporary heavy soiling
Wait until the soiling decreases
− Start-up phase of the filter system
− This operating status is atypical. Avoid long-term
(e.g. during the first start-up)
− Fish are spawning
Pond heavily soiled
− Clean the pond
− Reduce the amount of soiling
− Install the filter pump in an elevated position.
Screen elements heavily soiled
Clean the screen elements, descale (→ Replacing screen
element)
Insufficient cleaning effect due to soiled
− Clean nozzle
nozzle
Water level in the system too high:
− Outlet pipes soiled
− Clean outlet pipes
− Outlet opening too small
− Enlarge outlet opening
− Max. flow rate exceeded
− Reduce flow rate
− A large amount of dirt has entered
− Clean foam filters
the filter system, water is flowing
over (instead of through) the foam
filters.
Control system is exposed to excessive
Protect the control system from heat
heat (sun, ambient temperature)
Foam filters soiled
Clean foam filters (→ Cleaning foam filters)
the drum Only use original OASE grease (order number
27872).
sprocket
operation in this state.
- EN -
Resetting the system
message
Press
key for 5 s
− Press
key for 5 s
− Automatic if the number
of cleaning procedures
drops below 960.
Automatic when cooled down
Automatic after elimination of
the cause