Mark holes.
10. Install the Valve
CAUTION: Risk of product damage. This valve contains plastic and rubber components; do not apply
excessive heat near the valve or apply flux or acids directly onto the valve.
CAUTION: Risk of product damage. Inlet and outlet threaded connections should be made using
sealant tape or liquid sealant. Do not use oil-based, non-setting compounds, such as plumbers putty, on
the threaded connections.
Route the 3/4" dedicated water supply lines. To allow access to the inlet screens for periodic
cleaning, install a removable segment of piping to the valve inlets using unions.
Install supply shut-off valves and water hammer arrestors in the supply lines prior to the valve.
Hold the valve up to the install location and verify fit.
Mark the hole locations.
Predrill the holes.
Secure the valve with the washers and screws. Do not overtighten.
IMPORTANT! Make sure the components are connected to the corresponding numbered outlet(s) on the
valve according to your chosen showering configuration, refer to the "Component Configurations" section.
Route the piping from the valve outlets to the appropriate shower components based on your
chosen configuration.
If utilizing a custom configuration, plug any unused outlets.
Connect the supply lines to the valve inlets. Verify that the hot and cold supplies are connected to
the appropriate inlets. Hot is red and marked by a "H," cold is blue and marked by a "C."
Secure all piping to the framing.
1043183-2-B
3/4" NPT Hot Inlet
Washers
Screws
14
Plug unused outlets.
Shut-Off Valve
Water
Hammer
Arrester
Kohler Co.