ELECTRICAL REQUIREMENTS
Single Advantium Built-In Oven Installation:
This product requires a 120-volt, 60 Hz, 15-amp
circuit and draws 1.8 kilowatts. This product must be
connected to a supply circuit of the proper voltage and
frequency.
• Wire size must conform to the requirements of the
National Electrical Code or the prevailing local code for
this kilowatt rating.
• The power supply cord and plug should be brought
to a separate 15 or 20 ampere branch circuit single
grounded receptacle. The outlet box should be located
within reach of the 48" power cord.
GROUNDING INSTRUCTIONS
WARNING
Improper use of the grounding plug can result in a risk of electric shock.
This appliance must be grounded.
In the event of an electrical short
circuit, grounding reduces the risk
of electric shock by providing an
escape wire for the electric current.
Ensure Proper ground
exists before use.
This appliance is equipped with a
power cord having a grounding wire with a grounding
plug. The plug must be plugged into an outlet that is
properly installed and grounded.
Consult a qualified electrician or service technician if
the GROUNDING INSTRUCTIONS are not completely
understood, or if doubt exists as to whether the
4
Installation Preparation
ELECTRICAL LOCATION
Locate outlet box in the shaded area
Install a recessed electrical outlet
in the back wall of the opening
within 6 of either side and at least
9 above the cutout floor.
appliance is properly grounded.
If the outlet is a standarf 2-prong wall outlet, it is your
personal responsibility and obligation to have it replaced
with a properly grounded 3-prong wall outlet.
Do not under any circumstacnes cut or remove the third
(ground) prong from the power cord.
Do not use an extension cord. If the power cord is too
short, have a qualified electrician or service technician
install an outlet near the appliance.
For best operation, plug this appliance into its own
electrical outlet to prevent flickering of lights, blowing of
fuse or tripping of circuit breaker.
6"
9"
31-2000354 Rev. 0