Certificates and approvals
● Explosion protection for Canada (to
CSA
)
C
US
● Certificate of Compliance
Marking (XP/DIP)
Permitted ambient temperature
Entity parameters (XP/DIP)
Marking (ia/ib)
Permitted ambient temperature
Entity parameters
Marking (NI/n)
Permitted ambient temperature
NI/nA parameters
nL parameters
Trademarks
All names identified by ® are registered trademarks of the Siemens AG. The remaining trademarks in this publication may be trademarks
whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot
be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any
necessary corrections are included in subsequent editions.
Siemens AG
Industry Sector
Postfach 48 48
90026 NÜRNBERG
SITRANS P500 with HART
18
A5E02344532, 09/2010
No. 2280963
CL I, DIV 1, GP ABCD T4 /T6;
CL II, DIV 1, GP EFG T4/T6
T
= T4: -40 ... +85 °C (-40 ... +185 °F)
a
T
= T6: -40 ... +60 °C (-40 ... +140 °F)
a
To "control drawing":
U
= 45 V
max
CL I, Ex ia/Ex ib IIC, T4;
CL II, III, Ex ia/Ex ib, GP EFG, T4;
CL I, AEx ia/AEx ib IIC, T4;
CL II, III, AEx ia/ AEx ib, GP EFG, T4
T
= T4: -40 ... +85 °C (-40 ... +185 °F)
a
U
= 30 V, I
= 100 mA, P
i
i
R
= 300 Ω , L
= 400 μH, C
i
i
CL I, DIV 2, GP ABCD T4/T6;
CL II, III, DIV 2, GP FG T4/T6;
Ex nA IIC T4/T6;
AEx nA IIC T4/T6;
Ex nL IIC T4/T6;
AEx nL IIC T4/T6
Ta = T4: -40 ... +85 °C (-40 ... +185 °F)
Ta = T6: -40 ... +60 °C (-40 ... +140 °F)
To "control drawing":
U
= 45 V
m
To "control drawing":
U
= 45 V, I
= 100 mA,
i
i
L
= 400 μH, C
= 6 nF
i
i
= 750 mW,
i
= 6 nF
i
SITRANS P500 with HART
A5E02344532-02, 09/2010