Electric Start; Starting The Engine; Stopping The Engine - Black Max BM10680 Serie Manual Del Operador

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

OXYGENATED FUELS
DO NOT USE E85 FUEL. IT WILL VOID YOUR
WARRANTY.
NOTE: Fuel system damage or performance problems re-
sulting from the use of an oxygenated fuel containing more
than the percentages of oxygenates stated previously are
not covered under warranty.
Ethanol. Gasoline containing up to 10% ethanol by vol-
ume (commonly referred to as E10) or 15% ethanol by
volume (commonly referred to as E15) are acceptable.
Do not use E85 fuel.
CAUTION:
On a level surface with the engine off, check the lubricant
level before each use of the generator.

ELECTRIC START

This generator model is provided with both electric start and
recoil start capabilities. Avoid prolonged cranking, as it can
damage the engine.
The battery provided is a nominal 12 volt sealed recharge-
able lead-acid battery and can be operated in any position
without leakage. It complies with non-spillable battery
regulations. Its convenient size offers a 30% reduction over
conventional batteries.
NOTE: Brand new generators are shipped with the battery
connections disconnected. The positive and negative ter-
minals must be connected to the battery before the Electric
Start feature will work.
For initial battery connection, see Connecting/Disconnect-
ing Battery.
OPERATION

STARTING THE ENGINE

See Figures 11 - 14.
NOTE: If location of generator is not level, the unit may not
start or may shut down during operation.
 Unplug all loads from the generator.
 Turn the fuel valve to the ON position.
 Move the choke to the CLOSED position.
NOTE: If engine is warm or the temperature is above
50˚F, move the choke to the OPEN position.
 Using the switch key, turn the engine switch to "ON"
 Turn the engine switch to "START" and release after engine
starts, or pull the starter grip and rope until the engine
runs (a maximum of 6 times).
NOTE: Do not allow the grip to snap back after starting;
return it gently to its original place.
 Allow the engine to run for 30 seconds, then move the
choke to the OPEN position.

STOPPING THE ENGINE

See Figures 11 - 13.
To stop the engine under normal operating conditions:
 Remove any load from the generator.
 Turn the fuel valve to the OFF position.
 Using the switch key, put the engine switch in the OFF
( O ) position.
To stop the engine in an emergency situation:
 Using the switch key, turn the engine switch to OFF.
Page 14 — English
Tabla de contenido
loading

Tabla de contenido