System configuration (Connections)
wConnection of the Indoor Pan-tilt Head AW-PH405
p Turn off the power of all the equipment before proceeding with the connections.
p Connect the AC power cable provided with the AW-PH405 to the AW-PH405 indoor pan-tilt head.
p Use 10BASE-T straight cables to connect the RP connectors on the pan-tilt heads with the CONTROL OUT TO PAN/TILT
HEAD (1 to 5) connectors on the AW-RP655 multi-function controller and AW-RP555 multi hybrid control panel.
The maximum extension distance is 1000 m when using UTP category 5 cables or their equivalent.
p Connect the CONTROL OUT TO PAN/TILT HEAD terminals (P1 to P5) of the AW-RP400 and the CONTROLLER terminal of
the protocol converter AW-IF400 using a 10BASE-T straight cable when using the AW-RP400 pan/tilt control panel.
The maximum extension distance is 500 m when using UTP category 5 cables or their equivalent.
Connect the PAN/TILT HEAD terminal of the protocol converter AW-IF400 and the RP terminal of the AW-PH405 with a
10BASE-T straight cable.
The maximum extension distance is 1000 m when using UTP category 5 cables or their equivalent.
p Use the camera cable provided with the pan-tilt head to connect the AW-PH405 to the unit.
p Connect the iris control cable of the motorized zoom lens to the IRIS connector on the camera, and connect the zoom/focus
cable to the LENS I/F (1) connector on the pan-tilt head.