5.3.2 Rear view
1 = 3-pole screw connection for connecting cable
2 = Battery compartment with 2 x AA batteries or corresponding AA batteries
5.3.3 Error message
If [Sensor!] appears when preparing a test
or during testing, the rail pressure sensor of
the pressure pickup or pressure pickup
module may possibly not be connected
correctly.
In such cases check that the cable is
connected correctly to the digital pressure
gage and to the pressure pickup or pressure
pickup module, and that there is no open
circuit in the cabling or the connectors.
- 11 -