3E4 – ALL MODELS
1- Turn OFF the machine by pressing button "A"
On/Off.
2- Unscrew the cap of salt container located
inside the tank by turning it anticlockwise.
(Fig.44)
Fig.44
3- Pour approx. 1 kg of coarse salt [NaCI] in the
container. (Fig.45)
Fig.45
4- Screw the cap of salt container by
turning it clockwise.
WARNING!
ONLY SALT MUST BE PLACED INSIDE THE
SALT CONTAINER. DO NOT INTODUCE ANY
OTHER CHEMICAL SUBSTANCES SUCH AS
DETERGENT, RINSE AIS OR DESCALING
AGENT, SINCE THESE WOULD INEVITABLY
DAMAGE THE APPLIANCE. SUCH DAMAGE
INVALIDATES ANY WARRANTY AND RELIEVES
THE MANUFACTURER OF ALL LIABILITY
3E5 – RESINS CHART RANGE
Water Hardness
20°F
(french degrees)
Water Liters
240
Treatment
Cycles Number
120
3E6 – WATERSOFTENER REGENERATION
It is important to follow the Resins Chart Range
in order to have correct regeneration with the
watersoftener.
1- Ensure that salt container is full.
2- Turn OFF the machine by pressing button "A"
On/Off.
3- Open the door and remove the water flow
device. (Fig.46)
Fig.46
.
30°F
40°F
150
120
75
60
4- Drain out completely the water from the
tank. For models with Drain Pump see
par. 3D.
5- Keep
pressing
for
regeneration button on the control panel
until it starts regeneration process.
(Fig.47) On electronic version, keep
pressing button "C" until Regeration icon
will be on the display.
Fig.47
- The machine automatically complete the
regeneration process in approx. 18 min.
few
seconds
18