Problems
The roller shutter does not stop
when it reaches the lower end
limit position.
The roller shutter does not stop
when it reaches the upper end
limit position.
6.2 Restoring the original configuration
6.2.1 Using the control point connected to the roller
shutter
Caution: Follow each of the 4 steps in the procedure care-
fully to correctly restore the original configuration.
1)
Place the roller shutter in the mid-height position.
2)
Caution: Repeat the next step 3 times in succession
-
Press the Up button until the roller shutter moves.
Release the button immediately.
3)
Caution: Repeat the next step twice in succession
-
Press the Down button until the roller shutter moves.
Release the button immediately.
4)
Press the Down button again until the roller shutter makes
2 successive movements in the same direction.
The motor has been reinitialised with the original
configuration. Repeat the commissioning process.
6.2.2 Using the wired electronic motor setting tool
- Press the Up and Down buttons on the setting tool at the
same time until the roller shutter makes an initial up and
down movement followed by a second one.
The motor has been restored with the original config-
uration. Repeat the commissioning process.
7. Technical specifications
Power supply
Operating temperature
Index protection rating
Copyright © 2007 - 2008 Somfy SAS. All rights reserved.
Possible causes
The mountings used are not
correct.
The roller shutter locking system
in the upper position is not
correct.
Solutions
Check that the roller shutter is
mounted to the roller tube using
rigid links or bolts.
Check that the roller shutter is
fitted with end stops screwed
onto the last slat, fixed or remov-
able stops incorporated in the
runners or an end slat acting as
an end stop.
1
2
3
4
x 2
7s
230V/50 Hz ~
- 20°C to + 70°C
IP 44
ilmo 50 WT
x 3
25