SICK CLV69 Serie Instrucciones De Servicio página 96

Escáneres de códigos de barras
6
INSTALACIÓN ELÉCTRICA
Wire "Result 1 ... 4" switching outputs of the CLV69x in the CDM490-0001 connection module
CLV69x
U
V
Result X
GND
2 "I/O" connection
CLV69x
CDM490-0001
Result X
Pin Y
Pin Y
Name
Result 1
4
4
Result 1
Result 2
8
8
Result 2
Result 3
10
10
Result 3
Result 4
15
15
Result 4
Characteristic data of "Result 1 ... 4" switching outputs
Switching
PNP switching to supply voltage
behavior
U
(+24 V*).
V
CLV69x default settings:
Result 1: device ready (static), logic: active high
Result 2: good read, 100 mm, logic: active high
Result 3: no function assigned
Result 4: no function assigned
Properties
– Short-circuit protected + temperature protected
– Not electrically isolated from U
Electrical
0 V ≤ U
≤ U
a
V
values
Guaranteed:
(U
− 1.6 V) ≤ U
V
Figura 96: Cableado de salidas conmutadas "Result 1 a 4"
96
I N S T R U C C I O N E S D E S E R V I C I O | CLV69x
Cable, e.g.
No. 2020302 (3 m)
2
1
.
.
.
Y
5
10 5
1
6 1
5
10
D-Sub-HD
11
15
15
11
Terminal Z
Result X
41
Result 1
42
Result 2
43
Result 3
44
Result 4
(+24 V*)
V
≤ U
at I
≤ 100 mA
a
V
a
CDM490-0001
(I/O card)
1
+24 V* (U
)
V
Shield
5
Y
Name
Z
5
GND
45
GND
U
= DC 18 ... 30 V
6
V
With inductive load:
Sweep-out circuit:
Attach a freewheeling diode
directly to the load.
Load (e.g. PLC)
Result X
U
a
8025632/131W/2019-03-06 | SICK
Sujeto a cambio sin previo aviso

Capítulos

loading