Technical data
Parameter
Can be used as per
EN 62061
1)
PFH
D
TM mission time
Door signal output
(semi-conductor output,
p-switching, short circuit
2)
proof)
Output voltage
Load rating
Rated insulation voltage
U
i
Rated transient
withstand voltage U
imp
Rated conditional short
circuit current
Resistance to vibration
Operating delay as of
3)
state change
4)
Risk period
Discrepancy time of both
safety outputs
5)
Start-up delay time
6)
Dwell time
Switching frequency
Repeatability R in
accordance with
EN IEC 60947-5-3
Mounting distance
between two read heads
or two actuators
EMC protection
requirements
1)
Using the limit value from EN ISO 13849-1:2008, section 4.5.2
(MTTF
= max. 100 years), the BG certifies a PFH
d
2)
Values for a switching current of 50 mA without consideration of the cable length.
3)
Corresponds to the risk time in accordance with EN 60947-5-3. This is the maximum
switch-off delay of the safety outputs after withdrawal of the actuator.
4)
The error detection time is the time of an internal device error. At least one of the two
semiconductor outputs is switched off safely.
5)
When the operating voltage is switched on, the semiconductor outputs are switched off
and the signal contacts set to LOW potential during the start-up delay.
6)
The dwell time of an actuator inside and outside the operating range must be at least
0.5 seconds to ensure a safe detection of internal errors in the evaluation unit (self-
detection).
Value
min.
typ.
SILCL 3
2.1 x 10
20 years (EN ISO 13849)
0.8 x U
V DC
B
max. 100 A
In accordance with IEC/EN 60947-5-2
0.5 s
M 10 %
80 mm
To IEC/EN 60947-5-3
of max. 2.47 x 10
d
Operating Instructions
T4000 Direct Unicode
max.
–9
/h
U
V DC
B
200 mA
75 V DC
1.5 kV
290 ms
300 ms
10 ms
10 s
1 Hz
-8
/h.