SICK T4000 Serie Instrucciones De Servicio página 151

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Operating Instructions
T4000 Direct Unicode
WARNING
© SICK AG • Industrial Safety Systems • Germany • Subject to change without notice • 8012206/UC32/2010-11-15
Installation
When changing the direction of approach, ensure you do
not damage, trap or chafe any cables.
 Remove the top part of the base and push the bottom
part of the base off the read head (Fig. 3, ).
 Unscrew the mounting bracket screws and pull the
mounting bracket off the read head (Fig. 3, ).
 Tip the read head forward by 90°; the sensing face is
now pointing down (Fig. 3, ).
 Turn read head by 180° and re-fit the mounting bracket
to a torque of 0.6 Nm (Fig. 3, ).
 Turn read head to the required direction of approach
and then push the bottom and top part of the base back
onto the read head (Fig. 3, ).