Specifications; Power Supply - Promax PROFI-70 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

1.2

Specifications

TUNING
Tuning range
Tuning mode
Channel plan
Sensibility
Indication
LEVEL MEASUREMENT
Measurement
Input A
Measuring range
Maximum input level
Input B
Measuring range
Maximum input level
Readout
Wait time for packets
IF bandwidth
Input connectors
DATALOGGER FUNCTION
Max. number of loggers
Measurements
SCAN
Span
Dynamic range

POWER SUPPLY

NiMh battery
Low battery indication
Autonomy
Battery charge
Mains to charger adapter
1
Because of safety reasons, the maximum input power over the entire band is limited up to +30 dBm. The
equivalent power level for a group of channels of similar levels is related with the input power level over the
entire band according to the following expression:
L T = L+10 log N (L T : total level , L: mean level of one channel, N: number of channels present).
For higher input power levels, the use of an external attenuator of 20 dB is recommended.
Page 2
From 2412 to 2484 GHz (ISM band).
By channels.
(CH1 - CH14)
(IEEE 802.11 / 802.11b/g standard).
- 90 dBm.
Panoramic graphical LCD with automatic back
lighting.
Power measurement in the channel bandwidth by
detection method.
From -90 to -20 dBm.
1
+10 dBm
From -50 to +20 dBm.
1
+30 dBm
In dBm. 1 dB resolution
From 50 to 10000 ms (in 50 ms steps)
22 MHz
SMA female 50 Ω
50
Channel, SSID, MAC, Encryption, Power and
Signal/Noise ratio.
100 MHz (14 channels)
70 dB
12 V
Graphic indication on the display:
Approximately 3 hours.
By fast internal charger.
100 V — 240 V AC / 50-60 Hz (EUROPE and other
countries).
USER'S MANUAL. PROFI-70
02/2007
Tabla de contenido
loading

Tabla de contenido