6.3
SPACE NECESSARY FOR USE
The choice of the place and space required for installation is an important
factor for the quality of work and safety and for correct maintenance
activities. This area must not only be spacious enough to allow for optimum
equipment operation - also during cleaning and maintenance phases - but
must also be well lit, aired, not dusty and not exposed to direct sunlight.
Note also that the unit must be positioned so the connection plug can be
handled/manipulated with ease.
6.3.1 WORKTOP
Fig. F: Hurrimix
2
mixer has been designed to work on a rigid worktop and
parallel to the ground. Suitable worktops include service furniture (operator
is standing) or modelling tables (operator is sitting). All worktops must be
checked for stability.
6.4
CONNECTION TO ENERGY SOURCES
The connection is made using the power supply cable. Check:
• that mains power supply voltage and frequency correspond to those
indicated on the identification plate (an incorrect power supply voltage
may damage the equipment);
• that the power supply mains has a suitable earth connection.
Position the appliance in such a way that the mains plug (which
serves as the disconnection device) is easily accessible.
Do not tamper with the power supply cable and relative plug.
For replacement of the same due to damage and/or wear, only
contact Authorised After-Sales Centres.
An earth connection is mandatory. Should you
need to use an extension, make sure it's earthed.
Hurrimix
is designed to be used in the electromagnetic environment specified below. The client or user must ensure that it is used in such an environment.
2
Emission test
RF emissions
CISPR11
RF emissions
CISPR11
Harmonic emissions
IEC 61000-3-2
Voltage fluctuations/ flicker emissions
IEC 61000-3-3
Hurrimix
is designed to be used in the electromagnetic environment specified below. The client or user must ensure that it is used in such an environment.
2
Emission test
RF emissions
EN 55011
RF emissions
EN 55011
Harmonic emissions
EN 61000-3-2
Voltage fluctuations/ flicker emissions
EN 61000-3-3
hurrimix
2
hurrimix
115Vac/60 hz
2
Guide and manufacturer's declaration – electromagnetic emission
Compliance
Hurrimix
uses RF energy only for its internal operation. Therefore, its RF emissions are very
2
Group 1
low and are unlikely to cause any interference in nearby electronic devices.
Class B
Hurrimix
2
can be used in any environment, including domestic ones and those connected
Class A
directly to a public low-voltage power supply network, which supplies buildings for
domestic purposes.
Compliant
hurrimix
230Vac/50 hz
2
Manufacturer's declaration and guidance – electromagnetic emission
Compliance
Hurrimix
uses RF energy only for its internal operation. Therefore, its RF emissions are very
2
Group 1
low and are unlikely to cause any interference in nearby electronic devices.
Class B
Hurrimix
can be used in any environment, including domestic ones and those connected
2
Class A
directly to a public low-voltage power supply network, which supplies buildings for
domestic purposes.
Compliant
The reference figures are present on pages 3, 4, 5 and 6 of this manual and in the product Quick Guide.
6.5
START-UP
Remove the safety knobs under the device before beginning
mixing (Fig. E).
Fig. 1: Place the equipment level on the work bench.
Fig. 2: Insert the main power socket into the appropriate outlet at the rear of
the device and subsequently connect the plug to the mains. In this regard,
strictly follow the indications described in paragraph 6.4.
Fig. 3: Switch on the device, pressing the I/0 main switch (fig.A, 4).
Fig. 4: Then press the ON/OFF/open door button on the control panel for
two seconds (fig. A, 7).
To turn off, press the ON/OFF/open lid button (fig. A, 7) then
press the main I/O switch (fig. A, 4).
Failure to comply with any of the above-stated equipment
installation regulations can lead to equipment malfunctioning
and render the warranty null and void.
6.6
ELECTROMAGNETIC COMPATIBILITY
As an electromedical device, Hurrimix
regarding electromagnetic compatibility and must be commissioned in
compliance with the information below.
Radio frequency communication systems (mobile and portable)
may affect this electromedical device.
• As an electromedical device, Hurrimix
next to or on top of other equipment. Should it be necessary,
it is important to observe whether the performance of both
pieces of equipment is affected by a possible unwanted
electromagnetic coupling.
• The power cord must be the one provided. If damaged,
replace it with an equivalent one supplied by Zhermack.
Do not use the machine empty, ie without the mixing bowls
provided.
Electromagnetic environment - Guidance