PROGRAMMING PROCEDURE

(gate travel distance and current sensor)
The installation of anti-derailment buffers is absolutely obligatory.
Make sure the safety devices are at rest and the ECU is receiving mains power
otherwise you will not be able to enter programming.
menu.
T B
F I
Press and hold down prog/ok for 4 seconds
PROGRAM
F S
CP
"PROG/OK" for 4 sec.
T B
F I
PAUSE
F S
CP
AUTO PROG.
"PROG/OK"
T B
F I
The pause time count will start (min. 2 seconds: max.
PAUSE 005
120 seconds) indicated by "PAUSE" and the elapsed
F S
CP
AUTO PROG.
time appearing on the display
"PROG/OK"
Press "PROG" to set the pause time to the required value.
T B
F I
OPENING
The door will now open slowly in order to find the
F S
CP
completely open position.
AUTO PROG.
When the gate reaches the completely open travel limit it will
invert the travel direction and after moving a few centimetres
it will open again to confirm the completely open position. At
AUTO-PROGRAMMING
this point the gate will start to close. When the gate reaches
CYCLE
the completely closed travel limit it will invert the travel
direction and after moving a few centimetres it will close
again to confirm the completely open position.
T B
F I
CLOSING
After having carried out this manoeuvre the logic control will
F S
CP
open then close the gate completely in order to calibrate
AUTO PROG.
the current sensor.
When the gate reaches the completely closed position the
T B
F I
programmer saves the parameters and quits the programming
F S
CP
mode.
T B
F I
PROGRAM
The operation has not succeeded. You will have to
F S
CP
repeat the programming procedure.
REPOSITIONING
Attention! During the repositioning manoeuvre the current sensor value
could be altered. At the end of the manoeuvre, however, it will reset
automatically to the chosen value.
If the programmer blocks due to an encoder count error
play), after a programmer reset
motor
the warning lights and indicator light will flash simultaneously for
2 seconds and will then switch off for 10 seconds.
If in this stage you send a (TA, TC, TAL or TD) command to the programmer.
The programmer will move the gates slowly to the completely closed position (2 times
as in the programming procedure) in order to recover the correct position.
positioning recovery is carried out in the opening direction.
No commands will be accepted during repositioning but the security devices will cut
in and block all movement if they go into alarm.

REMOTE CONTROL

The system can be remotely activated using radio control devices; each channel
has a choice of 6 possible functions: open - shut - limited opening - sequential
command - stop.
To set the functions to channels A B C D
open-stop-shut-stop
open-close
1...4... sec.
or when there is a problem with the
TA
PROG
TB
The sequential command may be set to
Memory module (M1)
This is extractable, furnished with a non volatile EEPROM type memory and contains
the transmitter codes and allows you to memorise up to 300 codes. The programmed
codes are maintained in this module even during blackouts.
Before memorising the transmitters for the first time remember to cancel the entire
memory content.
If the electronic card has to be replaced due to failure, the module can be extracted
from it and inserted into the new card. Make sure that the module is correctly
inserted as shown in fig. 3.
TRANSMITTER CODE MANAGEMENT
Memorising a channel
2. Activate the transmitter channel that is to be memorised:
3. Activate the transmitter again (same transmitter, same channel
The number of channels already present in the memory is shown on the first line
in brackets.
*
if the channel is different or it is a different transmitter (point three) the memorisation
attempt will abort without success
Note: It is not possible to memorise a code which is already in memory: if you attempt
this the indication
Cancelling a channel:
2. Activate the transmitter channel that is to be cancelled:
3. Activate the transmitter again (same transmitter, same channel
The number of channels already present in the memory is shown on the first line
in brackets.
*
if the channel is different or it is a different transmitter (point three) the cancellation
attempt will abort without success
Note: It is not possible to cancel a code which is not already in memory: if you
attempt this the indication
Cancelling all user codes from memory:
procedure).
display.
Memorising ulterior channels via radio
The system can be remotely activated using radio control devices; (without opening
menu.
1. Using a transmitter, in which at least one channel
A, B, C or D
in the receiver, press the button in the transmitter
as shown in figure.
-
Note: all the receivers within range when the channel
button is pressed (and which have at least one of the
2. Press one of the channel buttons on the same transmitter. The receivers which do
deactivate. The receivers which contain the channel code will sound a one-second
3. Press the previously chosen channel buttons on the transmitter which you wish to
receiver will be ready to receive another code.
4. To leave the programming mode wait for 3 seconds without pressing any buttons.
ming mode.
Note:
the memory is full.
Note: the memo radio procedure can only be carried out after programming has
terminated and you have quit the setting/programming menu.
20
*
):
*
):
programming via radio" mode.
programming via radio
programming via radio
-