GAS CYLINDER REQUIREMENTS

The grill is set and tested with LPG gas only. The regulator supplied for use with LPG gas only. The factory-supplied regulator and hose
must be used with a 9 kg (20 lbs) (Diameter: 318 mm, Height: 475 mm) LP gas tank. Contact your gas supplier for a special regulator
for bulk gas that fuels other appliances.
CAUTION: It is important to inspect the full length of the gas line hose. If it is evident there is excessive abrasion
or wear, or the hose is cut, the hose must be replaced prior to the appliance being used. Use Regulator comply
with EN 16129 and local regulations.

CONNECTION FOR CONNECTOR

Note: The connector kit is not included if the regulator is pre-assembled.
CONNECTOR A
Connector A for Countries: BE, CZ, SK, SL, DK, IE, GB, IS,
LU, CO, RO, MLT, CYP, LTU, EST, LVA, ISR, ES, PT, FI, NO, GR,
IT, SE, BUL, HU
CONNECTION FOR CONNECTOR A
1.
Insert connector tapered end into the regulator tube, then lock tight
by using the hose clamp. See A1.
2. Loop in the connector into the metal ring, then into the manifold,
tightening completely. See A2.
Note: if there's no metal ring included, ignore this step.
3.
Connect the regulator to the gas cylinder, open the cylinder making
sure the knob is in the OFF position. Spread soapsuds all over the joint
between the connector and the regulator tube, and between the manifold and the connector. Check if there's any gas leakage. If
leakage is found, tighten the connector or the manifold again until there is no leakage observed.
CONNECTION FOR CONNECTOR B
1.
Screw in the male connector threaded end into the regulator tube
threaded female end. Tightening completely. See B1.
2. Loop in the connector into the metal ring, then into the manifold,
tightening completely. See B2.
Note: if there's no metal ring included, ignore this step.
3.
Connect the regulator to the gas cylinder, open the cylinder making
sure the knob is in the OFF position. Spread soapsuds all over the joint
between the connector and the regulator tube, and between the manifold and the connector. Check if there's any gas leakage. If
leakage is found, tighten the connector or the manifold again until there is no leakage observed.

CONNECTING TO A GAS SUPPLY

CONNECTOR B
Connector B for Countries: FR
A1
A2
B1
B2
7