Maintenance; General Maintenance; Troubleshooting - EGO Power+ LB4800 Manual De Funcionamiento

Ocultar thumbs Ver también para Power+ LB4800:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

maintenance

WARNING:
When servicing, use only identical replacement parts. use of any
other parts may create a hazard or cause product damage. to ensure safety and
reliability, all repairs should be performed by a qualified service technician.
WARNING:
to avoid serious personal injury, always remove the battery pack
from the product when cleaning or performing any maintenance.

gENERaL MaINTENaNCE

avoid using solvents when cleaning plastic parts. most plastics are susceptible to
damage from various types of commercial solvents and may be damaged by their use.
use clean cloths to remove dirt, dust, oil, grease, etc.
WARNING:
Do not at any time let brake fluids, gasoline, petroleum-based
products, penetrating oils, etc., come in contact with plastic parts. Chemicals can
damage, weaken or destroy plastic which may result in serious personal injury.
STORagE
 Clean all foreign material from the air inlets of the blower.
 Store indoors in a place that is inaccessible to children. Keep away from corrosive
agents, such as garden chemicals and de-icing salts.
20
56V litHium-iOn COrDleSS BlOWer — lB4800

troublesHootinG

pROBLEM
CaUSE
 the battery pack is not
attached to the blower.
 no electrical contact
between the blower
and battery
 the battery pack is
depleted.
 the battery pack or
Blower doesn't work.
blower is too hot.
 the switch is operated
too frequently in a
short time. pCB self-
protection.
 excessive wearing of
motor fan.
the air velocity
decreases obviously.
 the air inlet is blocked
by debris.
56V litHium-iOn COrDleSS BlOWer — lB4800
SOLUTION
 attach the battery pack
to the blower.
 remove battery, check
contacts and reinstall
the battery pack.
 Charge the battery
pack.
 Cool the battery pack
and blower until the
temperature drops
below 152°F (67°C).
 the blower is
equipped with soft
start technology. Wait
for the motor to start
up smoothly when
the trigger switch is
depressed.
 Contact egO service
center for repair.
 remove the battery
pack, clear the debris.
21

Capítulos

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Lb4800