System set-up
4.1- Power supply line wiring
Inside the transformer compartment there is a terminal with a 2 A protection
fuse, connect the phase in the corresponding pole to the fuse.
4.2- Wiring for flashing light, courtesy light and gate movement warning light:
1
2
M
Motor 1
Pedestrian
Terminal
Description
number
1-2
Output for powering the electric motor 1
(pedestrian)
3-4
Output for powering the electric motor 2
5-9
Courtesy light or second radio channel
6-7
Output for electrical lock control
8-9
Gate movement warning output
9-10
Accessories power supply output
11-12
Output for flashing light
4.3- Input connections:
The control unit is supplied with jumpered normally closed inputs (stop, photo and stpa) remove the jumper from the input you are going to use.
13 14 15 16 17 18 19
EN
5
3
4
-
Electrical lock
M
Motor 2
12 Vdc 120 mA max
Courtesy light or
second radio channel
Function
Output for controlling electric motor 1, 12 Vdc rated power 50 W (1 opening, 2 closing)
Output for controlling electric motor 2 at 12 Vdc rated power 50 W (3 opening, 4 closing)
Output 12 Vdc maximum load 120 mA, can be programmed as a timed output (100 seconds) or
second radio channel output, see dip switch number 6 (5= GND, 2can/ 9= + 12 Vdc).
Output for electrical lock at 12 Vac maximum 15 VA
Gate movement warning output, flashes slowly when opening, on steady with gate open,
flashes quickly during closing and off with gate closed (8 = controlled GND, 9 = permanent +
12 Vdc, maximum load 120 mA)
Output 12 Vdc maximum 300 mA for supplying the photocells and accessories (9 = + 12 Vdc,
10= GND)
Output at 12 Vdc maximum load 15 W for flashing light (11 = flashing light GND, 12 = + 12 Vdc),
if the automatic closing function is active, the flashing light is on steady during the time of
automatic closing.
Terminal number
13-16
14
15
17
18
19
6
7
8
9 10 11 12
-
+
-
12 V 15 VA
Accessories power supply output
12 Vdc 300mA max
12 Vdc 120mA max
Gate movement
warning light
Description
Control inputs common (permanent GND)
Sequential control input, to govern the
complete travel of the gate
Sequential control input, to govern the
pedestrian travel of the gate
Input for stopping the gate
Photocell input, active during gate closing
Input for edges or internal photocell, active
during gate closing and opening
Neutral
neutro
Phase
fase
-
+
12 Vdc 15 W max
Input type
_
Normally open
Normally open
Normally closed
Normally closed
Normally closed
Terra
Fig. 4
Fig. 5
17