System Setup - Vimar RS01 Manual Para El Conexionado Y El Uso

Tarjeta con trimmer 12 vdc para cancelas correderas
Ocultar thumbs Ver también para RS01:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 42
RS01
System set-up
4.1- Power supply line wiring
Inside the transformer compartment there is a terminal with a 2 AT protection fuse, connect the phase in the corresponding pole to the fuse.
4.2- Wiring for flashing light, courtesy light and gate movement warning light
N.B.: Do not change the motor output wiring (terminals 1 and 2) the dip switch 2-2 selects the direction of opening.
Terminals
1-2
3-4
Courtesy light or second radio channel
4-5
Warning light output
6-7
Accessories power supply output
8-9
Output for flashing light
The sum of the absorptions of the 2CAN, AUX and -VA outputs must not exceed 500mA.
CN2
10 11 12 13 14 15 16
Fuse 2 A L 250 V (Mains: 230 V, 240 V)
Fuse 4 A L 250 V (Mains: 110 V, 117 V, 125 V)
- + -
+
white
M
Electric
Accessories power
motor
supply output
12 Vdc 120mA max
12 Vdc 120mA max
Courtesy light or
Gate movement
warning light
second radio channel
Description
Motor output
Output 12 Vdc maximum load 85mA, flashes slowly when opening, on with stationary
open gate, flashing fast when closing and off with gate closed (4= +12 Vdc / 5= GND).
Input description table:
The control unit is supplied with jumpered normally closed inputs (stop, photo and stpa) remove the jumper from the
input you are going to use.
Terminal number
10-13-18
11
Sequential control input, to govern the complete
12
14
15
16
17
19
-
- +
12 Vdc 15 W max
Output for controlling electric motor 12 Vdc rated power 50 W
COM
COM
(terminal number 1 white, terminal number 2 brown)
Output 12 Vdc maximum load 85mA, can be programmed as a timed output (60
seconds) or second radio channel output, see dip switch number 6
N.O.
N.C. N.C.
(3 = GND / 4 = +12 Vdc).
Output 12 Vdc maximum 300 mA for supplying the photocells and accessories
(6 = +12 Vdc, 7= GND)
Output 12 Vdc maximum load 15 W for flashing light (8 = GND, 9 = + 12 Vdc).
Description
Control inputs common (permanent GND)
travel of the gate
Sequential control input, to govern the
pedestrian travel of the gate
Input for stopping the gate
Photocell input, active during gate closing
Input for edges or internal photocell, active
during gate closing and opening
Closing limit switch input, if the magnetic limit
switch is on (optional)
Opening limit switch input, if the magnetic limit
switch is on (optional)
EN
Fig. 4
Fig. 5
Function
N.O.
RX1
Input type
-
+
-
C NC NA
normally open
normally open
+
Normally closed
- -
COM
Normally closed
FOT
Normally closed
If not used, leave free
If not used, leave free
RX2
+
-
C NC N
15
Tabla de contenido
loading

Este manual también es adecuado para:

Elvox rs01