10. SOLUTIONS TO MOST FREQUENT ANOMALIES
ANOMALY
Protection magneto-thermal
Motor does not start
Bluntness of the blade
segments or diamond bands
Cutting power
insufficient
Water level low in the tray
The cooling water
does not reach the
blade
The pump water tap is closed
Blade premature
damage
The machine is not aligned
Defective cutting
Blade damaged or blunt
Blade deteriorated or worn-
Apparition of
Blade subjection defect
vibrations
POSSIBLE CAUSE
Power supply faulty
Wait until the motor cools down and reactivate
activated
Starter defect
Blade blocked
Inappropriate blade
Motor low potency
Pump blocked
Pump damaged
Insufficient cooling
Excessive advance
Inappropriate blade
out
Blade oscillation
Blade twisted
SOLUTION
Check the power supply in the switch board.
Check the position of the thermal magnet and
the differential in the switch board. Make sure
the extension cable is in a good state and well
plugged in both ends
the thermal protection START.
Replace it
Remove the obstacles that prevent its rotation
Effectuate different cuts on an abrasive
material (Sandstone, concrete, stone emery)
Use appropriate blade for material
Let a technician check the motor
Fill in water to level
Dismount the tape filter and clean it
Replace the pump
Open the water tap
Check the cooling
Decrease advance
Use adequate blade for material to cut
Align according the instruction manual
Replace the blade
Use adequate blade for material to cut
Check the state of the blade and mount it
correctly
Make sure the flanges and the motor axis are
well adjusted. Tighten well the nut.
Replace the blade
-13-
ENGLISH