10. SOLUTIONS TO MOST FREQUENT ANOMALIES
ANOMALIA
Motor does not
start up
Thermal protection activated (single-
Motor arranca muy
lentamente y tarda
Damaged condenser. (Single phase
demasiado en
alcanzar sus
revoluciones
Bluntness of the disk segments or
Cutting power
insufficient
The cooling water
does not reach the
disk
The pump water tape is closed
Disk premature
damage
Defective cutting
Vibrations
occurrence
POSIBLE CAUSA
Power supply fault
phase switches)
Damaged switch
Blocked disk
motors)
diamond bands
Inappropriate disk
Motor low potency
Water level low in the tray
Pump blocked
Pump damaged
Insufficient cooling
Excessive advance
Inappropriate disk
The machine is not aligned
Disk deteriorated or worn-out
Inappropriate disk
Disk oscillation
Disk subjection defect
Wrapt the disk
- 13 -
SOLUCION
Check the power supply in the switch board. Check
the position of the thermal magnet and the
differential in the switch board.
Make sure the extension cable is in a good state and
well plugged in both ends
Wait until the motor cools down and switch on the
thermal protection
Replace it
Eliminar los obstáculos que impiden su giro
Replace it
Effectuate different cuts on an abrasive material
(Sandstone, concrete, stone emery)
Use appropriate disk for material
Let a technician check the motor
Fill in water to level
Dismount the tape filter and clean it
Replace the pump
Open the water tape
Check the cooling
Decrease the advance
Use appropriate disk for material
Align as per the manual
Change disk
Use appropriate disk for material
Check the state of the disc and mount it correctly
Make sure the bridles and the motor axis are well
adjusted. Tighten well the nut.
Change the disk
ENGLISH