3.12 Installing the G1 Push-to-Connect Regulator

DO NOT use the respirator unless the regulator is connected properly. A regulator that is not
installed correctly can separate from the facepiece unexpectedly.
Failure to follow these warnings can result in serious personal injury or death.
There must be a continuous flow of air when the bypass knob is opened. If not, do not use the respi-
rator.
Failure to follow these warnings can result in serious personal injury or death.
(1)
Grasp the regulator and insert it into the facepiece by
pushing inward.
If properly aligned the bypass knob will show on the
right side of the user's facepiece.
(2)
Check proper engagement by pulling on the regulator
to ensure that the regulator is securely attached to
facepiece.
WARNING
(3)
Inhale sharply to start the air flow.
(4)
Check the bypass again by turning the red knob
counter-clockwise until increased air flow is felt. Close
the bypass.
WARNING