Replacing The Head Harness; Replacing The Exhalation Valve Disc; Replacing The Lens - MSA ADVANTAGE 3100 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 20
3.2
Disinfection
Masks should be disinfected after having been
cleaned as described above.
The disinfectant MSA AUER 90 or MSA Cleaner
Sanitizer is recommended. Information about the
concentration and time is contained in the
Instructions for Use of disinfectant. After disin-
fecting thoroughly, flush all components with
water, dry and reassemble (see table 5 for disin-
fection intervals).
4
Maintenance
Maintenance of the full face mask must be
performed by the maintenance technician (if there
is none, by the user). It includes the visual check,
the functioning and leak tests, as well as replacing
components.
4.1
Visual and Function Test
The visual and function test serves to identify
damaged components and functional disorders,
especially at the valves and harness. In case of
doubt about the functioning of a component, it
must be replaced immediately or the MSA AUER
customer service must be contacted.
Part of the visual test is to ensure adherence to the
test intervals according to Sect. 5.
4.2
Leak Test
The leak test is performed with the MSA AUER
leak test kit; its operation is described in the kit's
Instruction Manual.
The MSA AUER Customer Service should be con-
sulted prior to using leak test kits of other manu-
facturers.
4.3
Replacement of Components
Only MSA AUER spare parts must be used for
repair. After the replacement of components a
complete test must be done.

4.3.1 Replacing the Exhalation Valve Disc

To replace the exhalation valve disc, remove the
cover from the connector and unbutton the exha-
lation valve. After fitting a new exhalation valve,
the cover is reassembled. Make sure the cover
snaps into place all the way.

4.3.2 Replacing the Lens

Loosen screws on lens ring, remove both lens ring
halves (Fig. 5) and take out lens. Remove cover,
loosen clip (Fig. 6) and push connector (towards
inside) out of lens.
Insert connector (from inside) into new lens,
secure with clip and reassemble cover. Prior to
8
inserting the new lens, assure that the groove of
the faceblank is completely clean. Insert the lens,
centrally aligned, into the faceblank, fit the lens
ring, also centrally aligned, and reassemble.

4.3.3 Replacing the Head Harness

Unbutton the buckles of the neck strap. Turn the
flexible plastic harness that is in the hinge on the
lens ring way downward (faceblank will deform)
and remove from hinge. Assemble new head
harness in reverse order.
Fig. 5
Fig. 6
Tabla de contenido
loading

Tabla de contenido