Signs And Symbols Used; Putting Into Operation - Abicor Binzel PP Instructivo De Servicio

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

4 Putting into operation

Coolant connection
Cooling unit power
Control leads
Weight/meter
Machine-side connections
Tab. 4
Cable assembly
Size
0.8 / 0.8 mm
1.0 / 1.0 mm
1.2 / 1.2 mm
1.6 / 1.6 mm
Tab. 5
Wire feed rolls PP

3.2 Signs and symbols used

In the operating instructions, the following signs and symbols are used:
Symbol Description
List of symbols for action commands and enumerations
Cross reference symbol refers to detailed, supplementary or further information
1
Action(s) described in the text to be carried out in succession
4 Putting into operation
DANGER
Risk of injury due to unexpected start-up
The following instructions must be adhered to for the entire duration of maintenance,
servicing, mounting, dismounting and repair work:
• Switch off the power source.
• Close the gas supply.
• Close off the compressed air supply.
• Disconnect all electrical connections.
• Switch off the entire welding system.
EN - 6
PP
Plug-in nipple NW5
min. 800 W
2/2/3-wire
approx. 0.7 kg
Central connector WZ-2 (liquid-cooled),central
connector KZ-2 (air-cooled)
Material
Steel/Aluminium
Steel/Aluminium
Steel/Aluminium
Steel/Aluminium
BAL.0212.0 • 2018-07-16
PP