4 Putting into operation
4.2 Mounting the liner
NOTICE
• New still unused liners or PA liners have to be shortened to the actual length of the cable
assembly.
4.2.1 Liner
To be used for steel wires.
1
9
1
Torch neck
2
Inlet nipple
3
Wire conduit
Fig. 2
Liner
1 Lay down the cable assembly (9) straight and unscrew nut (6) from central connector (4).
2 Slide the liner (8) through the wire conduit (3) until a noticeable resistance is felt in the inlet
nipple (2).
3 Determine excess length x and pull out the liner (8) again.
4 Shorten the liner (8) by the dimension x.
5 Debur the cutting point and sharpen the spiral beginning to an angle
of 40°.
6 Insert the liner cut to length (8) into the wire conduit (3).
7 Screw down nut (6) and secure with multiple wrench (5).
EN - 8
2
40°
8
4
Central connector
5
Multiple wrench
6
Nut
3
4 – 5 mm
x
7
7
Holding nipple
8
Liner
9
Cable assembly
BAL.0212.0 • 2018-07-16
PP
4
5
6