Defining the schedule to be applied
1. Hold down the TIMER switch for more than 3 seconds and the SET indicator appears. All
the days and schedule numbers are indicated.
2.Press
DAY switch until the day to be set flickers.
By pressing it, the day flickers
[Mon] [Tue]
...
[Sun] [Mon~Sun] [Mon~Fri] [Sat, Sun] [Mon]...
In case of flickering various days, the same setting is applied to the days.
3. Press the SCHEDULE
4. Press the switch, and the SCHEDULE indication appears. Then the schedule number
indicated in step 3 is applied to the days set in step 2. Press the OK switch to activate or
deactivate the schedule. If the schedule is activated, the word SCHEDULE is lit up.
5. Press the TIMER switch and the SET indicator goes out, and the mode returns to normal.
Cancelling the timer
In normal mode, press SELECT
SCHEDULE indicator blinks. (Cancellation of all the timer)
During the TIMER cancellation mode, press SELECT
seconds. NEXT SCHEDULE is indicated. (Timer activation)
Setting the temperature shifts (energy saving mode)
1. Perform the ON/OFF time setting operation of sub-chapter point 1 and 2, and then select
"S" as a schedule number
2. Set the ON/OFF operation in steps 4,5 and 6 of the "Setting the timer" section, and set the
ON/OFF time. The temperature setting is then indicated.
3. Select the temperature to shift by
reset switch is pressed, shift temperature is not performed indicating "- -". When the TIMER
switch is pressed, the temperature is indicated and the mode changes to schedule number
selection.
4. When the TIMER switch is pressed, the SET and SCHEDULE indicators go out and the
mode returns to normal.
NOTE:
1. When this operation is performed, the temperature shift indicator changes.
2. When this operation is performed, the temperature setting of the CS-NET or PSC-5S has a normal range, while the
remote control setting may be changed to a new range.
3. The increase or decrease in the temperature setting during the scheduled time (±3 ºC or ±5 ºC) varies according to the
operation mode.
- If the system is operating in FAN, COOL or DRY mode, the temperature variation is + .
- If the system is operating in HEAT, mode, the temperature variation is - .
switch until the schedule number you wish to set blinks.
switch simultaneously more than 3 seconds. The NEXT
switch. "3" or "5" can be selected. In this time, if